Power on
Use the Storage Utility to configure the following settings for the K2 RAID controller:
•
IP address
•
Subnet mask
•
Gateway Address
•
SNMP trap destinations
For K2 RAID, network and SNMP settings are set and stored on the RAID controller module. For
the RAID chassis with two controllers, each controller has its own network settings and the RAID
chassis exists as two entities on the control network.
The RAID storage device is configured by default for the SNMP community name “public”. If your
site’s policies require using a different SNMP community name, contact your Grass Valley
representative.
1. Launch Storage Utility from the K2Config application.
2. As prompted, wait while Storage Utility gathers system information, then Storage Utility opens.
3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID
controller, and select
Configuration | Network Properties
.
The Controller Network Settings dialog box opens.
4. In the Controller Slot Number field enter
0
and then press
Enter
.
The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
02 February 2012
K2 SAN Installation and Service Manual
215
Configuring and licensing the K2 SAN