3. In Storage Utility tree view, expand the node for the K2 RAID, right-click the icon for a RAID
controller, and select
Configuration | Network Properties
.
The Controller Network Settings dialog box opens.
4. In the Controller Slot Number field enter
0
and then press
Enter
.
The settings from controller 0 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
5. Enter the control network IP address and other network settings.
6. For SNMP Configuration, enter the IP address of the NetCentral server PC.
You can also enter IP addresses for other SNMP managers to which you want to send SNMP
trap messages.
7. For the RAID chassis with two controllers, in the Controller Slot Number field enter
1
and then
press
Enter
.
The settings from controller 1 are loaded into the Controller Network Settings dialog box and
are available for you to modify.
8. Repeat the previous steps to configure controller 1.
9. Click
OK
to save settings and close.
10. In Storage Utility click
View | Refresh
.
Next, bind disk modules.
02 February 2012
K2 SAN Installation and Service Manual
161
Configuring and licensing the K2 SAN
Summary of Contents for K2 BASECAMP EXPRESS
Page 28: ......
Page 38: ......
Page 62: ......
Page 112: ......
Page 124: ......
Page 248: ...248 K2 SAN Installation and Service Manual 02 February 2012 Operating the K2 SAN ...
Page 256: ......
Page 340: ......
Page 354: ......
Page 366: ...366 K2 SAN Installation and Service Manual 02 February 2012 Index ...