Pump Control Modules and Tank Control Modules
located in each hazardous location can be set up
locally, using the keypad and display to access and
change the software settings.
Use the control module software to:
• Place the control module in Remote Control
mode. See
for Modbus Communication, page 47
and
Set Up a Tank Control Module for Modbus
Communication, page 48
.
• Set the baud rate for control module
communication. The baud rate must match
the baud rate of the Supervisor Module.
See
Set Up a Pump Control Module for
and
Set Up a Tank Control Module for Modbus
Communication, page 48
.
• Set up the Reed Switch, Agitator Halt Drum Cover
Switch, Primary Tank High and Low Alarm Output,
and Auxiliary Solenoid. See
Module Configurable I/O, page 49
and
Tank Control Module Configurable I/O, page 51
• Enter the unique node ID generated by the
Intelligent Paint Kitchen software for the control
module. See
Configure Each Station, page 64
.
See the E-Flo DC Control Module Kit manual 3A2527
or the Tank Control Module Kit manual 3A5991
for complete warnings and operating instructions,
including how to use the keypad to access and
change the software settings.
Figure 46 Control Module Keypad and Display
Key
Key
Key
Name
Name
Name
Function
Function
Function
Toggle
Toggle between Run screens
and Setup screens.
Error
Reset
Clear alarm after cause has
been fixed. When there is no
alarm to clear, this key sets
the active pump’s profile to
Stop. Also used to cancel data
entered and return to original
data.
Up Ar-
row-
/Down
Arrow
Move between screens or fields
on a screen, highlight data
to change, or to increase or
decrease the digits in a field.
Enter
Activate a field for editing or
accept the highlighted selection
on a menu.
Enter
Screen
Highlight data that can be
edited. Also can change the
function of the Up/Down arrows
so they move between data
fields on the screen, rather than
between screens.
Exit
Screen
Exit data editing.
46