Use fiber optic cables to connect each fiber optic
converter to a Pump Control Module (PD). If
the paint kitchen contains both a Pump Control
Module and a Tank Control Module (TD), connect
them together using a fiber optic cable. See the
table.
1.
Disconnect the power.
2.
Connect the Tank Control Module (if used) in the
hazardous location to the Pump Control Module,
also in the hazardous location:
a.
Plug the two connectors at one end of cable
(FA) into Port 1 and Port 2 on the Tank
Control Module.
b.
Plug the two connectors at the other end
of cable (FA) into Port 5 and Port 6 on the
Pump Control Module.
3.
Connect the Pump Control Module in the
hazardous location to a fiber optic converter
in the Supervisor Box in the non-hazardous
location:
a.
Plug the two connectors at one end of cable
(FB) into Port 1 and Port 2 on the Pump
Control Module.
b.
Plug the two connectors into the RX and TX
Ports on a fiber optic converter inside the
Supervisor Box.
Wire
Wire
Wire
Color
Color
Color
Orange with red ends
Orange with black
ends
Hazardous
Hazardous
Hazardous Location
Location
Location
Non
Non
Non---hazardous
hazardous
hazardous
Location
Location
Location
Tank
Tank
Tank
Control
Control
Control
Module
Module
Module
Pump
Pump
Pump
Control
Control
Control
Module
Module
Module
Figure 38
38
3A4030C