Use the Tank Control Module (TD) keypad and
display to set up configurable inputs and outputs.
1.
Press the Toggle key to enter the Setup screens
of the Tank Control Module.
2.
Use the Up Arrow and Down Arrow keys to
navigate to Setup Screen 3.
3.
Press the Enter Screen key to enter the screen
and edit the settings.
4.
Use the menu next to the I/O icons
and
to select the option for the connected
peripheral. Control the auxiliary solenoid by
updating the information next to the icon
.
Figure 57 Setup Screen 3 (Agitator Halt and
Secondary Tank Low Alarm Output Shown)
Setup
Setup
Setup Screen
Screen
Screen 3
3
3 Key
Key
Key
Select reed switch input or agitator
halt
to configure digital input for
Port 4, Pin 2.
Agitator halt status
or
Reed switch cycle rate
Select one of the following to
configure digital input/output for Port
4, Pin 4 :
Reed Switch Input
Primary Agitator Halt Input
Primary Tank High Alarm Output
Primary Tank Low Alarm Output
Secondary Tank Low Alarm
Output
General Purpose Output
Select the manual output box
and hold the button
to control the auxiliary solenoid
manually. After you release the
button, the manual activation is
terminated.
5.
When all control module settings are correct,
press the Exit Screen key to exit setup mode.
Set
Set
Set Up
Up
Up a
a
a Radar
Radar
Radar Level
Level
Level Sensor
Sensor
Sensor Using
Using
Using
the
the
the Keypad
Keypad
Keypad
Use this procedure to connect a Radar Level Sensor
(M, T) to a Pump Control Module (PD) or Tank
Control Module (TD) using the keypad.
NOTE:
NOTE:
NOTE: The following steps describe connections to
a Graco-approved Radar Level Sensor. If you are
not using a Graco-approved Radar Level Sensor,
contact your distributor.
1.
Set up the primary Pump Control Module and
primary Tank Control Module.
a.
For the primary Pump Control Module, turn
on power to Port 9 using setup screen 17.
Figure 58 Turn on Power for the Primary
Pump Control Module
b.
For the primary Tank Control Module, turn on
power to Port 8 using setup screen 1.
Figure 59 Turn on Power for the Primary
Tank Control Module
2.
Set up the secondary Tank Control Module. Turn
on power to Port 9 using setup screen 1.
Figure 60 Turn on Power for the Secondary
Tank Control Module