Display
Display
Display
Code
Code
Code
Applicable
Applicable
Applicable
Motor
Motor
Motor
Blink
Blink
Blink
Code
Code
Code
Type
Type
Type
Description
Description
Description
L1A0
None
Alarm
The flow rate is above the current profile flow limit set on
Profile Screen 3.
L2A0
None
Deviation The Primary Tank level is below the Primary Tank level low
deviation set point.
L4A0
None
Alarm
The Primary Tank level is above the Primary Tank level high
alarm set point.
L6CA
None
Deviation Port 8 is enabled and the current draw is less than 4 mA.
The Back Pressure Regulator is requesting a value greater
than 0%.
L6CB
None
Deviation Port 9 is enabled and the current draw is less than 4 mA.
MND_
Advanced
None
Advisory Maintenance counter is enabled and countdown reached
zero (0).
P1D_
Advanced
None
Deviation Unbalanced load. Dual Lower system — P1D1 = Motor 1 is
requiring less force to hold speed; pump lower may need
service. P1D2 = Motor 2 is requiring less force than motor
1 to hold speed.
P9D_
Advanced
None
Deviation Major unbalanced load — see P1D_ (P9D_ is higher
magnitude)
P1I_
Advanced
1–3
Alarm
Pressure is below minimum limit.
P2I_
Advanced
None
Deviation Pressure is below minimum limit.
P3I_
Advanced
None
Deviation Pressure exceeds maximum target.
P4I_
Advanced
1–4
Alarm
Pressure exceeds maximum target.
P5DX
Advanced
None
Deviation More than one pump is assigned to a transducer. The
assignment for that transducer is automatically cleared under
this condition. User must reassign.
P6CA or
P6CB
Advanced
None
Deviation For units without closed loop pressure control: Transducer
(A or B) is enabled but not detected.
P6D_
Advanced
1–6
Alarm
For units with closed loop pressure control: Transducer is
enabled but not detected.
T2D_
Basic and
Advanced
3–5
Alarm
Internal thermistor disconnected or motor temperature is
below 0° C (32° F).
T3D_
Basic and
Advanced
5
Deviation Motor over temperature. Motor will throttle itself to stay below
85° C (185° F) internally.
T4D_
Basic and
Advanced
4–6
Alarm
Motor over temperature. Motor will throttle itself to stay below
85° C (185° F) internally.
V1I_
Basic and
Advanced
2
Alarm
Brown out; voltage supplied to motor is too low.
V2I_
Basic and
Advanced
None
Deviation Brown out; voltage supplied to motor is too low.
V1M_
Basic and
Advanced
2–6
Alarm
AC power is lost.
V3I_
Basic and
Advanced
None
Deviation Voltage supplied to motor is too high.
3A4030C