![background image](http://html1.mh-extra.com/html/graco/25a693/25a693_instructions-manual_2251038115.webp)
Ref.
Ref.
Ref.
Item
Item
Item
Description
Description
Description
13
Actual RPM
Current agitator blade speed.
• Direct Drive: 0-500 RPM
• Back Gear: 0-50 RPM
14
Set Point
Set point for agitator:
• Percentage: 0 -100%
• Hertz:
– Direct Drive: 2-18 Hz
– Back Gear: 2-43 Hz
• RPM:
– Direct Drive: 55-500 RPM
– Back Gear: 2.4-50 RPM
15
Actual Level
Current tank level percentage.
16
Last Tank Level
Last tank level at which the agitator speed was updated when using
agitator profiles.
17
On Time
Current on time for the agitator in minutes when using agitator profiles.
18
Off Time
Current off time for the agitator in minutes when using agitator profiles.
19
Load
Current agitator load as a percentage of the drivers output current rating.
20
Profiles
Each column (#1–#2) displays the settings of an agitator profile. When
one of these profiles is selected, the chosen column is highlighted in
green.
21
Profile Select
Press one of the following to choose the profile and set operation
parameters for the agitator:
Turn off the pump.
Turn off the pump.
Select Profile 1, if created.
Select Profile 2, if created.
3A4030C