Improper wiring may cause electric shock or other
serious injury if work is not performed properly.
• This equipment must be grounded. Connect
only to a grounded power source.
• All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
NOTICE
NOTICE
NOTICE
If power and grounding connections are not done
properly, the equipment will be damaged and the
warranty voided.
The Supervisor Box (A) is rated for 100–240 VAC,
50-60 Hz, with a maximum of 1 amp current draw.
Not included with the system:
Power disconnection,
branch circuit protection, and power supply cord.
NOTE: A means of disconnect must be provided
during installation. Branch circuit protection of 15
amp maximum must be provided during installation.
Power wires must be made of copper and have a
minimum temperature rating of 60°C (140°F). The
wire gauge size must be 12–14 AWG.
1.
Turn off power rocker switch (2) to ensure the
Supervisor Box (A) is off.
2.
Open the electrical enclosure door.
3.
Route the power cable through the strain relief in
the bottom of the box.
NOTE: Strain relief or conduit connection to the
opening must be provided, according to electrical
requirements.
4.
Tighten the strain relief.
5.
Connect the supply ground wire to the protective
earth ground terminal (7b) provided in the
enclosure.
6.
Connect the incoming power wires to the terminal
block (56) inside the Supervisor Box. Gently pull
on all connections to verify that they are properly
secured.
Figure 26 Connect Power to the Supervisor Box
7.
Torque terminals to 5.3 - 7.0 in-lb (0.6 - 0.8 N•m).
8.
Verify that all items are connected properly, then
close the electrical enclosure door.