Replace
Replace
Replace a
a
a Fiber
Fiber
Fiber Optic
Optic
Optic Converter
Converter
Converter
1.
Disconnect the power.
2.
Disconnect the + (white/blue) and – (blue)
electrical wires.
3.
Remove the fiber optic converter (38) from the
DIN rail.
4.
Attach the new fiber optic converter (38) to the
DIN rail.
5.
Connect the + (white/blue) wire to terminal C.
Connect the – (blue) wire to terminal B.
NOTE:
NOTE:
NOTE: In the Supervisor Box, the wires originate
from the Supervisor Module. In the Expansion
Box, the wires originate from the power supply.
Wire
Wire
Wire
Termi-
Termi-
Termi-
nal
nal
nal
Color
Color
Color
B
White-
/Blue
C
Blue-
/White
Figure 96 Connecting Fiber Optic Converter
Wires
Replace
Replace
Replace the
the
the Supervisor
Supervisor
Supervisor Module
Module
Module
1.
Disconnect the power.
2.
Disc (red, white/blue) wires from
connectors B, 7, and 8. Disconnect – (blue,
black) wires from connectors A, 5, and 6.
3.
Remove the Supervisor Module (36) from the
DIN rail.
4.
Install the new Supervisor Module onto the DIN
rail.
5.
Connect the + (white/blue) wire from the fiber
optic converter (38) to terminal A on the ACS.
Connect the – (blue/white) wire from the fiber
optic converter to terminal B.
6.
Connect the + (red) wire from the power supply
(35) to terminal 8 on the ACS. Connect the –
(black) wire from the power supply to terminal 6.
7.
Connect the + (red) wire from terminal 6 on the
Ethernet switch (37) to terminal 6 on the ACS.
Connect the – (black) wire from terminal 5 on the
Ethernet switch to terminal 5 on the ACS.
Wire
Wire
Wire
Color
Color
Color
Red
Blue
Black
White/Blue
Blue/White
Figure 97 Connecting the Supervisor Module
Wires
138