Table
Table
Table 7
7
7 Fields
Fields
Fields on
on
on the
the
the Primary
Primary
Primary Tank
Tank
Tank Setup
Setup
Setup Screen
Screen
Screen
Item
Item
Item
Description
Description
Description
Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Primary Tank
Select Yes
Yes
Yes if the selected station has a Primary Tank.
Select No
No
No if there is no Primary Tank installed.
Agitator Type
Select the type of agitator installed on the Primary Tank:
• None
None
None (Default)
• 60
60
60 Hz
Hz
Hz Direct
Direct
Direct Drive
Drive
Drive (Maximum frequency of 18 Hz)
• 60
60
60 Hz
Hz
Hz Back
Back
Back Gear
Gear
Gear (Maximum frequency of 43 Hz)
• 50
50
50 Hz
Hz
Hz Direct
Direct
Direct Drive
Drive
Drive (Maximum frequency of 18 Hz)
• 50
50
50 Hz
Hz
Hz Back
Back
Back Gear
Gear
Gear (Maximum frequency of 43 Hz)
For part numbers, see
Appendix F: Agitator Part Numbers, page 159
NOTE:
NOTE:
NOTE: When an Agitator Type is configured, the “Agitator” button appears. Use this
button to navigate to the Primary Tank Agitator setup.
Level Sensor
Type
Select the type of level sensor installed on this Primary Tank:
• None
None
None (Default)
• Radar
Radar
Radar
NOTE:
NOTE:
NOTE: When a Level Sensor Type is configured, the “Volume Configuration” button
appears. Use this button to navigate to the Primary Tank Volume Configuration setup.
Level Sensor
Location
Select the location where the Primary Tank radar sensor is plugged in:
• None
None
None (Default)
• Pump
Pump
Pump Control
Control
Control
• Tank
Tank
Tank Control
Control
Control
• Lenze
Lenze
Lenze
Actual Tank
Level
Displays the current fluid level in the Primary Tank. (Read Only)
High Level
Alarm
Enter a number to specify the tank level (0–100%) at which a Tank Level High alarm
is generated.
NOTE:
NOTE:
NOTE: 0% disables the Tank Level High alarm.
Low Level Alarm
Enter a number to specify the tank level (0–100%) at which a Tank Level Low alarm
is generated.
NOTE:
NOTE:
NOTE: 0% disables the Tank Level Low alarm.
Target Level
When using a fill pump, enter a number to specify the fluid level at which the fill pump
will turn off.
NOTE:
NOTE:
NOTE: The Target Level must be less than the High Level Alarm and greater than the
Fill Level.
Fill Level
Enter a tank level (0–100%) to trigger the fill pump to turn on.
74