Network Setup and Configuration
Configure
Configure
Configure the
the
the Supervisor
Supervisor
Supervisor Module
Module
Module
Use this procedure to view current network status
of each Supervisor Module (36) in the Intelligent
Paint Kitchen system, to change the network IP
configuration settings if necessary, and to confirm
communication by pinging the system.
NOTE:
NOTE:
NOTE: Do not modify these settings unless instructed
by Graco.
1.
Press
on any Run screen to enter the Setup
menu screen.
2.
Press Supervisor
Supervisor
Supervisor Configuration
Configuration
Configuration.
On the Supervisor Configuration screen, do the
following:
• Press Status
Status
Status to view the current network
settings. The read-only Supervisor Status
screen displays the current network settings.
Each Supervisor Module in the Intelligent Paint
Kitchen system is displayed as either Online
Online
Online
or Offline
Offline
Offline.
• Press IP
IP
IP Configuration
Configuration
Configuration to change the IP
configuration settings for the Supervisor
Module.
a.
On the read-only Supervisor Network
Configuration screen, press Edit
Edit
Edit Config
Config
Config.
b.
On the editable Supervisor Network
Configuration screen, press one of the
data fields to be changed. Use the popup
screen to enter the network setting.
Field
Field
Field
Value
Value
Value
IP Address
192.168.1.201
Subnet Mask
255.255.255.0
Gateway
192.168.1.1
c.
Repeat as needed, until all the network
configuration settings are correct.
d.
To enter the changes and have them take
effect, press Apply
Apply
Apply.
• Press Baud
Baud
Baud Rate
Rate
Rate to change the baud rate
settings for the Supervisor Module. Press
the Supervisor
Supervisor
Supervisor Baud
Baud
Baud Rate
Rate
Rate field and use the
popup screen to enter the setting. The default
is 57600. 38400 is also available. To enter
the changes and have them take effect, press
Apply
Apply
Apply.
Verify that the baud rate settings match
the settings for the Pump Control
Module and fiber optic converter. See
Set Up a Pump Control Module for Modbus
Communication, page 47
and
on the Fiber Optic Converters, page 32
.
3.
To change the IP configuration settings, press
IP
IP
IP Configuration
Configuration
Configuration. On the read-only Supervisor
Network Configuration screen, press Edit
Edit
Edit Config
Config
Config.
4.
Confirm that communication to the Supervisor
Box is working properly.
3A4030C