![background image](http://html1.mh-extra.com/html/graco/25a693/25a693_instructions-manual_2251038086.webp)
6.
Set up a profile for the pump located in the
selected station.
Each column (#1, #2, #3, and #4) in the table
contains the parameters for one profile. Press
each item’s data field and use the keypad that
displays to create each pump profile.
Item
Item
Item
Description
Description
Description
Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Number
The number for each pump profile displayed:
• 1–4 profiles
Name
The alphanumeric name for each pump profile displayed:
• 0–20 characters
Mode
Use the keypad to select the method used to determine when this profile is used:
• Flow
Flow
Flow: The Intelligent Paint Kitchen uses flow output from the pump to decide if
this profile should be used. In flow mode, the motor maintains a constant speed to
maintain the target flow rate, regardless of the fluid pressure, up to the pump’s
maximum working pressure.
• Pressure
Pressure
Pressure: The Intelligent Paint Kitchen uses output pressure from the pump to
decide if this profile should be used. In pressure mode, the motor adjusts the pump
speed to maintain the fluid pressure percentage. If the flow limit is reached before
the target pressure, the unit stops driving to the pressure (if set as an alarm).
Target Pressure
Use the keypad to enter the pump output pressure to be maintained when this profile
is used. Units of measure (%, X, or Y) are the Pressure Units set up for this pump.
See
Set Up E-Flo DC Pumps, page 68
.
Target Flow
Use the keypad to enter the output flow to be maintained by the pump when this
profile is used. Units of measure (liters, gallons, cc, or oz per minute) are the Volume
Units set up for this pump. See
Set Up E-Flo DC Pumps, page 68
BPR
Use the keypad to enter the setting of the back pressure regulator when this profile
is used by the pump. Unit of measure is the percent (0 to 100%) open setting of
the Back Pressure Regulator.
7.
Repeat step 6 to create additional profiles (up to
four maximum) for the selected pump.
If you do not need a profile, leave the column for
the unused profile set to 0.
86
3A4030C