Item
Item
Item
Description
Description
Description
Station Number
The current station number being displayed:
• 1–Maximum number of stations
Station Name
The alphanumeric name of the current station being displayed:
• 0–20 characters
Secondary Tank
Select Yes
Yes
Yes if the selected station has a Primary Tank.
Select No
No
No if there is no Primary Tank installed.
Agitator Type
Select the type of agitator installed on the Secondary Tank:
• None
None
None (Default)
• 60
60
60 Hz
Hz
Hz Direct
Direct
Direct Drive
Drive
Drive (Maximum frequency of 18 Hz)
• 60
60
60 Hz
Hz
Hz Back
Back
Back Gear
Gear
Gear (Maximum frequency of 43 Hz)
• 50
50
50 Hz
Hz
Hz Direct
Direct
Direct Drive
Drive
Drive (Maximum frequency of 18 Hz)
• 50
50
50 Hz
Hz
Hz Back
Back
Back Gear
Gear
Gear (Maximum frequency of 43 Hz)
For part numbers, see
Appendix F: Agitator Part Numbers, page 159
.
NOTE:
NOTE:
NOTE: When an Agitator Type is configured, the “Agitator” button appears. Use this
button to navigate to the Secondary Tank Agitator setup.
Level Sensor Type
Select the type of level sensor installed on this Secondary Tank:
• None
None
None (Default)
• Radar
Radar
Radar
NOTE:
NOTE:
NOTE: When a Level Sensor Type is configured, the “Volume Configuration” button
appears. Use this button to navigate to the Secondary Tank Volume Configuration
setup.
Level Sensor
Location
Select the level sensor:
• None
None
None
• Tank
Tank
Tank Control
Control
Control
• Lenze
Lenze
Lenze
Actual Level
Displays the current fluid level in the Secondary Tank. (Read Only)
Low Level Deviation
Enter a number to specify the tank level (0-100%) at which a Tank Level Low
deviation is generated.
NOTE:
NOTE:
NOTE: 0% disables the low tank deviation.
Low Level Alarm
Enter a number to specify the tank level (0-100%) at which a Tank Level Low alarm
is generated.
NOTE:
NOTE:
NOTE: 0% disables the low tank deviation.