1.
On the Lenze Variable Frequency Drive/Inverter
keypad, press
to go into Program mode.
2.
Set the P-codes to the following:
P
P
P---code
code
code
Setting
Setting
Setting
Description
Description
Description
P100 Start Control Source
03
Network Only
P101 Standard Reference
Source
06
Network
P102 Minimum Frequency
0.0
Hertz
P103 Maximum Frequency
60.0
Hertz
P121 TB-13A Digital Input
09
Network Enable
P122 TB-13B Digital Input
21
External Fault
NOTE: Wire in a motor thermal overload switch.
P194 Password
0
Allows the Supervisor Module to control the Variable
Frequency Drive/Inverter.
P400 Network Protocol
02
Modbus RTU
P410 Network Address
101–120 for a
primary agitator
121–140 for
a secondary
agitator
Set to the node ID generated by the Intelligent Paint Kitchen
for this Variable Frequency Drive/Inverter.
P411 Network Baud Rate
05
57600 bps
P412 Network Data Format
0.0
8 data bits, no parity, 2 stop bits
P425 Network Message
Time Out
10.0
Generate an Intelligent Paint Kitchen error after 10 seconds
of no data.
P426 Network Message
Time Out Action
1.0
If a timeout occurs, Variable Frequency Drive/Inverter halts
the motor it controls.