Ref.
Ref.
Ref.
Item
Item
Item
Description
Description
Description
5
Pneumatic Remote
Transfer Fill Pump
Status
Indicates the current status of the pump.
indicates that the pump is stopped.
indicates that the pump is transferring fluid to the Primary Tank.
6
Back Pressure
Regulator Status
Displays the current Back Pressure Regulator setting in %.
Press to display a keypad and change the Back Pressure Regulator
setting.
7
Primary Agitator
Status
Displays the operating speed (in RPM, Hz, or %) of the primary electric
agitator installed in the circulation.
Press to display a keypad and change the agitator speed.
8
Enable Primary
Agitator
Press the image of a Primary Tank to display the Primary Agitator Enable
popup screen. Use the popup to enable or disable the selected agitator.
If the agitator is operating, its blades are shown in motion on this screen.
—
Secondary Agitator
Status
Displays the operating speed (in RPM, Hz, or %) of the secondary electric
agitator installed in the circulation.
Press to display a keypad and change the agitator speed.
—
Enable Secondary
Agitator
Press the image of a Secondary Tank to display the Secondary Agitator
Enable popup screen. Use the popup to enable or disable the selected
agitator.
If the agitator is operating, its blades are shown in motion on this screen.
9
Tank Status
Read only. Displays the level of fluid in the Primary Tank.
10
Select Pump Profile
Press the image of the pump to display the Profile Select popup screen.
Use the popup to enable or disable a profile for the selected pump.
11
E-Flo DC Pump Status
Read only. Displays current operating conditions in the pump:
• Profile: Displays the profile (0–4) that is controlling the pump’s
operation.
• Mode: Off, Flow, or Pressure (If Off, the Profile is 0.)
• Cycles/min: Current speed of the pump in cycles per minute.
• Force: Current force that the pump is currently provided in a range
of 0—100%
• Flow Rate: Indicates the pump’s current flow rate in cycles/min, oz/min,
cc/min, Gallons/min, or Liters/min, as chosen when the pump was
set up.
• Current Pressure for pressure transducer 1: Port 7 Pump Control
Module
• Current Pressure for pressure transducer 2: Port 10 Pump Control
Module
12
Pump Size
Read-only. Displays the configured pump size for that station on the
Pump Control Module: 220 cc, 290 cc, 750 cc, 1000 cc, 1500 cc, 2000
cc, 3000 cc, 4000 cc
See
Set Up E-Flo DC Pumps, page 68
to change this setting if a different
size pump is installed.
13
Arrow
Closed loop pressure has been assigned to that pressure transducer.
Press
to view or change the pump output pressure. For more
information, see Setup Screens 8 and 9 in the E-Flo DC Control Module
Kit manual 3A2527.
3A4030C
105