background image

QUAD - 24V - 2M

INSTALLATION AND USER’S MANUAL

Control unit

ISTRUZIONI D’USO E DI INSTALLAZIONE

INSTRUCIONS D’UTILISATION ET D’INSTALLATION

INSTALLATIONS-UND GEBRAUCHSANLEITUNG

INSTRUCCIONES DE USO Y DE INSTALACION

ИНСТРУКЦИЯ ПО МОНТАЖУ

comunello.com

Cod. 91300169 - Rev. 01 - 30.04.15

Summary of Contents for QUAD - 24V - 2M

Page 1: ...D USER S MANUAL Control unit ISTRUZIONI D USO E DI INSTALLAZIONE INSTRUCIONS D UTILISATION ET D INSTALLATION INSTALLATIONS UND GEBRAUCHSANLEITUNG INSTRUCCIONES DE USO Y DE INSTALACION comunello com Co...

Page 2: ...STROKE ON OFF L6 SLAM LOCK ON OFF L7 COURTESY LIGHT ON OFF LEV MEN 1 FLASH ID LED L1 SOFT STOP ON OFF L2 SOFT START ON OFF L3 DS1 IN OPEN ON OFF L4 HOLD TO RUN ON OFF L5 FOLLOW ME ON OFF L6 PAUSE FLAS...

Page 3: ...3 COMUNELLO Copyright 2014 All right reserved ITALIANO MAX 20mm FIG 1 FIG 3 FIG 2 FIG 3B...

Page 4: ...2M ID Description Cable type Lenght 1m to 20m Lenght 20m to 50m 1 Main power supply FG7 CEI 20 22 CEI EN 50267 2 1 2x1 5mm2 2x2 5mm2 6A Motor power supply 2x2 5mm2 2x4 0mm2 2 Flashing light 2x0 5mm2 2...

Page 5: ...DS2 OPENING N C FOTOCELLULA 1 DS1 IN CHIUSURA N C PHOTOCELL 1 DS1 CLOSING N C PULSANTE PEDONALE N O PEDESTRIAN PUSH BUTTON N O F1 CN4 TRASFORMATORE TRANSFORMER 230 21 7V 7 5A BATTERIA TAMPONE BACK UP...

Page 6: ...right reserved 2N D CN1 CN5 F1 L24 L24 M1 M1 M2 M2 ABACUS connection diagram of the motors DELAY LED OFF DELAY OF THE MOTOR n 2 1 1 2 2 DELAY LED ON DELAY OF THE MOTOR n 1 Configuration 24V with M1 0V...

Page 7: ...ht reserved ITALIANO 2N D CN1 CN5 F1 L24 L24 M1 M1 M2 M2 RAM connection diagram of the motors DELAY LED OFF DELAY OF THE MOTOR n 2 1 1 2 2 DELAY LED ON DELAY OF THE MOTOR n 1 Configuration 24V with M1...

Page 8: ...L24 M1 M1 M2 M2 CONDOR connection diagram of the motors 1 2 DELAY LED OFF DELAY OF THE MOTOR n 2 Configuration MASTER ON THE LEFT SLAVE ON THE RIGHT MOTOR n 1 WITH CONTROL UNIT on the left RED with M...

Page 9: ...L24 L24 M1 M1 M2 M2 CONDOR 2 2 DELAY LED OFF DELAY OF THE MOTOR n 2 DELAY LED ON DELAY OF THE MOTOR n 1 1 2 1 2 Configuration MASTER ON THE LEFT SLAVE ON THE RIGHT MOTOR n 2 WITHOUT CONTROL UNIT on t...

Page 10: ...amento dei motori DELAY LED OFF DELAY OF THE MOTOR n 2 DELAY LED ON DELAY OF THE MOTOR n 1 1 1 2 2 Configuration MASTER ON THE RIGHT SLAVE ON THE LEFT MOTOR n 1 on the left RED with M1 BLACK with M1 M...

Page 11: ...legamento dei motori DELAY LED OFF DELAY OF THE MOTOR n 2 DELAY LED ON DELAY OF THE MOTOR n 1 Configuration MASTER ON THE RIGHT SLAVE ON THE LEFT 2N D CN1 CN5 F1 L24 L24 M1 M1 M2 M2 1 1 2 2 MOTOR n 1...

Page 12: ...rectives 2004 108 EC Directive EMC Directive 2006 95 CE Directive and that all the rules and or technical specifications shown below have been applied EN61000 6 2 EN61000 6 3 EN62233 2008 EN301489 1 E...

Page 13: ...trol of the gate must be installed in a position such as to ensure the user is not placed in danger The operator utilized to move the gate must be in compliance with the prescriptions of EN 12453 poin...

Page 14: ...ing of the photocells during opening is disregarded while during closing it causes reversal of the direction of movement SAFE2 input NC Tripping during opening causes momentary stopping of the gate on...

Page 15: ...eiver will subsequently accept both fixed code remotes and rolling code remotes although only the fixed part of the latter will be controlled thus effectively relinquishing the security of the rolling...

Page 16: ...comes steady on and the programming procedure will be completed If you wish to enable the Release Stroke function at the power set with the FORCE trimmer repeat the procedure described above press the...

Page 17: ...eceleration stage can be programmed on the control unit You can select one of 6 different power levels as follows ensure you have enabled Extended Menu 3 each combination of lit LEDs defines a level a...