Use the Pump Control Module (PD) keypad and
display to set up configurable inputs and outputs.
1.
Press the Toggle key to enter the Setup screens
of the Pump Control Module.
2.
Use the Up Arrow and Down Arrow keys to
navigate to Setup Screen 16.
3.
Press the Enter Screen key to enter the screen
and edit the settings.
4.
Use the menu next to the I/O icon
to select
the option for the connected peripheral.
Option
Option
Option
Icon
Icon
Icon
Screen
Screen
Screen
Function
Function
Function
Reed Switch
Configures Port 4 pin 4 as an
input to allow a reed switch to be
connected.
The current reed switch cycle rate
appears next to the cycle rate icon
in cycles per minute.
Agitator Halt Drum
Cover Switch
Configures Port 4 pin 4 as an input
to allow a pressure switch to be
connected. If the drum cover is lifted
while this configuration is properly
connected, the agitator shuts down.
The current input status
appears in the agitator status
field
. A Supervisor
Module is required for this function.
Primary Tank High
Alarm Output
Configures Port 4 pin 4 as an output
to allow for the connected device to
receive an alarm when the volume
of the Primary Tank is above the
value that is defined in the Primary
Tank High field
. This
value is a percentage of the total
volume of the Primary Tank.
Select the manual output
box
and hold the button
to control the output manually. After
you release the button, the manual
activation is terminated.
3A4030C