ADV100 • Functions description and parameters list
97
Power supply
The mains supply is restored while the function is enabled
Speed ref
Speed
Speed
Speed ref
Drv enable
Vdc
Powerloss
Next active
Powerloss
Ramp down
Powerloss
Next ratio
PowerLoss_05. vsd
Restart and mains supply restored
The drive switches itself off
if the power supply is not restored
Detection possible when the external sensor detects
that the mains supply has been restored
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
22.6.7 3440 Powerloss mains src
LINK 16
6000
0
16384
ERWZ F__
This parameter is used to select the origin (source) of the
Mains voltage OK
signal. The signal to be associated with
this function can be selected from the “L_DIGSEL2” selection list.
If the signal is not enabled it means the power supply is not present (
Mains voltage not OK
), whereas if the signal
is enabled it means the power supply is present (
Mains voltage OK
).
In the default condition the origin of the
Powerloss mains src
signal is
Zero
.
The user must connect an external sensor to inform the drive of the mains supply status.
If the function is configured as
Powerloss mode = Restart
, when the
Mains voltage OK
signal is enabled the drive
stops the deceleration ramp and passes to the set reference.
For machines with several drives the external sensor signal must only be connected to the master drive.
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......