114
ADV100 • Functions description and parameters list
Not all alarms allow the controlled stopping of the drive. The following table shows the possibility of setting the Activi-
ties for the individual alarm signals.
Alarm
Ignore
Warning
Disable drive
Stop
Fast stop
ExtFlt
ü
ü
ü
ü
ü
Motor OT
ü
ü
ü
ü
ü
Overspeed
ü
ü
ü
ü
ü
SpdRefLoss
ü
ü
ü
ü
ü
SpdFbkLoss
ü
ü
ü
ü
ü
Drive ovld
ü
ü
ü
ü
ü
Motor ovld
ü
ü
ü
ü
ü
Bres ovld
ü
ü
ü
ü
ü
HTsens
-
-
ü
ü
ü
InAir
ü
ü
ü
ü
ü
Desat
-
-
ü
-
-
IOverC
-
-
ü
-
-
OverV
-
-
ü
-
-
UnderV
-
-
ü
-
-
PhLoss
ü
ü
ü
ü
ü
GroundFault thr
-
-
ü
-
-
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.1
4500 Fault reset src
LINK 16
1218
0
16384
RW FVS
Selection of the origin (source) of the signal to be used for the command to reset the drive after an alarm. The termi-
nal that can be used for this function can be selected from among those listed in the “
L_DIGSEL2
” selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.2
4502 ExtFlt src
LINK 16
6000
0
16384
RW FVS
Selection of the origin (source) of the signal to be used as the input for the drive external fault alarm
ExtFlt
. The
terminal that can be used for this function can be selected from among those listed in the “
L_DIGSEL2
” selection list.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.3
4504 ExtFlt activity
ENUM
Disable
0
4
RW FVS
Setting of the behaviour of the drive in the event of an external fault alarm
ExtFlt
. This alarm indicates the interven-
tion of a drive external protection.
0
Ignore
1
Warning
2
Disable
3
Stop
4
Fast stop
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
24.4
4506 ExtFlt restart
ENUM
Disable
0
1
RW FVS
Enabling of automatic restart after the external fault alarm
ExtFlt
0
Disable
1
Enable
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......