ADV100 • Troubleshooting
149
E – MESSAGES
Note !
For more information see Quick start guide,
Index
Error message
shown on the
display
Sub-code
Description
1
Load default param
Condition:
may occur during loading of the parameter database saved in flash
normally appears in the following conditions: at initial power-on when a new firmware version is downloaded, when the regulation is
installed on a new size, when the region is changed.
If this message is displayed when the drive is already operating, this means that a problem has occurred in the parameter database saved
in Flash.
If this message is displayed the drive restores the default database, i.e. the one downloaded.
0001H-1
The database saved is not valid
0002H-2
The database saved is not compatible
0003H-3
The database saved refers to a different size from the current size
0004H-4
The database saved refers to a different region from the current region
Solution:
Set the parameters to the value required and perform
Save parameter
2
3
4
Option detect slot 1
Option detect slot 2
Option detect slot 3
Condition:
at power-on, the drive recognizes the presence of an optional card in one of the three expansion slots.
One of the three messages is shown on the display
0H-0
None
0004H-4
Can/DeviceNet
00FFH-
255
Unknown
0608H-
1544
Enc 1 EXP-DE-I1R1F2-ADL / EXP-DE-I1-ADL
Solution:
5
Autotune
Condition:
this may occur during the
Autotune
procedure
0
No error
1
The commands are not configured in Local mode.
Solution
: Execute the requested configuration
2
The Commands local sel parameter has not been configured from the keypad
Solution
: Execute the requested configuration
3
The motor plate data parameters have changed but the
Take parameters
command, PAR 2020, has not been executed
Solution
: Execute the
Take parameters
command.
4
The motor is not connected
Solution
: Connect the motor
5
While running self-tuning the ESC key was pressed or the enable contact was opened or an alarm occurred. The
Autotune
command was sent with the drive in the alarm condition
Solution
: Eliminate the reason for the alarm, remove the reason for the opening of the enable contact, reset alarms.
6
A setting performed by the
Autotune
function produced a parameter value outside the min or max range.
Solution
: Check the motor plate data or drive and motor sizes have been combined incorrectly.
7
The
Autotune
command was sent without being enabled.
Solution
: Close the enable contact before sending the
Autotune
command
8 ... 21
A setting performed by
Autotune
has reached a measurement method limit
Solution
: Check the motor plate data or the drive and motor sizes have been combined incorrectly.
Solution:
If the message appears with a value other than 0, follow the instructions supplied for each particular case and repeat
Autotune
.
This should be performed using the wizard function available from the keypad (STARTUP WIZARD) and the Tool software on the PC.
Pay attention to all motor plate data parmaeters, especially:
-
Rated speed
,
Motor rated speed
in rpm.
-
Rated frequency
,
Motor rated frequency
in Hz
-
Pole pairs
,
Motor pole pairs
Take care not to set the
Rated speed
parameter to the synchronous speed. The value of the
Rated speed
parameter must be less than:
[(
Rated frequency
* 60) /
Pole pairs
].
If the problem persists even after following the instructions supplied, confirm the values of the motor plate data parameters, execute the
Take parameters
command but not
Autotune
.
6
Power config
Condition:
may occur during recognition of power cards. If this message is displayed, it is not possible to drive the motor.
0020H-32
The power card is configured for a drive that is incompatible with the regulation card
0021H-33
The configuration of the power card is not compatible with the regulation card
0017H-23
The configuration required is not available on the power card
Solution:
Download the correct configuration on the power card
7
Save par failed
Condition:
during transfer of the parameters from the drive to the memory of the keypad
0H-0
Communication error
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......