44
ADV100 • Functions description and parameters list
parameters for a source of Null (0) or the value of 6002 for a source of One (1).
Another alternative is to configure the
Digital Enable src
and
Digital Start src
sources on the
BitX decomp mon
parameters, so that the Modbus or Fieldbus can then write the desired value on the
Dig word decomp
parameter.
Local
n
Remote
switching is performed with the variable value configured as
Loc/Remote src
, i.e. it can be a stand-
ard digital input, expansion digital input, Modbus, Fieldbus,
Dig Local/Remote
.
In the default condition, the associated variable is
Dig Local/Remote
, which is written by the
LOC
key from the key-
pad: switching is thus performed by pressing the
LOC
key.
For safety reasons,
Local
n
Remote
switching is only performed with
Terminal Enable = 0
.
Example 1
With the machine in automatic operating mode, the drive works in Remote -> Digital -> Fieldbus mode.
With the machine in manual operating mode, the drive works in Local -> Terminal -> Standard digital input mode.
If switching from automatic to manual machine operation, the drive must switch between Remote and Local mode. The
switch command must be sent via standard digital input or fieldbus.
Example 2
With the machine controlled from console A, the drive operates in Local -> Terminal -> Standard digital input mode.
With the machine controlled from console B, the drive operates in Remote ->Digital -> Expansion digital input mode.
When switching the control console, the drive must switch between Remote and Local mode. The switch command
must be sent via Standard digital input or Expansion digital input.
This configuration is allowed because the Terminal variables are available in the digital command selection lists.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.1
1000 Commands remote sel
ENUM
Terminals
0
1
RWZ FVS
This parameter defines the source of the command signals when the drive is used in the Remote mode.
The Enable command can only be set via hardware, connecting a positive voltage (+24VDC) to terminal 7.
0
Terminals
1
Digital
When the parameter is set to
Terminals
the source of the
Enable cmd mon
command is the
Enable
terminal (9)
and the origin of the
Start cmd mon
command is configured using the
Terminal Start src
parameter.
When the parameter is set to
Digital
the origin of the
Enable cmd mon
command is configured using the
Digital
Enable src
parameter and the origin of the
Start cmd mon
command is configured using the
Digital Start src
parameter.
If
Digital
is set to generate the
Enable cmd mon
command, as well as the variable associated with
Digital Enable
src
, the enable hardware command must also be sent to the
Enable
terminal.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.2
1002 Commands local sel
ENUM
Keypad
0
2
ERWZ FVS
This parameter defines the source of the command signals when the drive is used in the
Local
mode.
0
Terminals
2
Keypad
When the parameter is set to
Terminals
the source of the
Enable cmd mon
command is the
Enable
terminal (9)
and the origin of the
Start cmd mon
command is configured using the
Terminal Start src
parameter.
When the parameter is set to
Keypad
the origin of the
Enable cmd mon
and
Start cmd mon
commands is the Start
key. When
Keypad
is set to generate the
Enable cmd mon
command, as well as the Start key the enable hardware
command must also be sent to the
Enable
terminal (9).
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...