126
ADV100 • Functions description and parameters list
4044
FieldbusM->S3
4054
FieldbusM->S4
4064
FieldbusM->S5
4074
FieldbusM->S6
4084
FieldbusM->S7
4094
FieldbusM->S8
4104
FieldbusM->S9
4114
FieldbusM->S10
4124
FieldbusM->S11
4134
FieldbusM->S12
4144
FieldbusM->S13
4154
FieldbusM->S14
4164
FieldbusM->S15
4174
FieldbusM->S16
4454
Bit0 decompMon
4456
Bit1 decompMon
4458
Bit2 decompMon
4460
Bit3 decompMon
4462
Bit4 decompMon
4464
Bit5 decompMon
4466
Bit6 decompMon
4468
Bit7 decompMon
4470
Bit8 decompMon
4472
Bit9 decompMon
4474
Bit10decompMon
4476
Bit11decompMon
4478
Bit12decompMon
4480
Bit13decompMon
4482
Bit14decompMon
4484
Bit15decompMon
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11018 Start PID
ENUM
Not Active
0
1
RW FVS
Parameter for selecting the source of the command to enable the PID controller. If this command is not active when
the PID is enabled, the PID will be in the STOP condition, the PID controller will not function and the drive will be
disabled.
When Digital Param is selected the source of the Start PID command corresponds to the value set in PAR 11018
Start PID
.
0
Not Active
1
Active
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
12000 Pid Output
rpm INT32
0
0
16384
R
FVS
This variable displays the PID output: it can assume values of 0 to 16384 and if used as the drive speed reference
the value of 16384 corresponds to the value set in PAR 680
Full scale speed
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
12004 Pid State
ENUM
Disable
0
5
R
FVS
This variable displays the current state of the PID controller.
0
Disable
1
PID
2
Stop
3
Alarm
4
Wait
5
Pressure const
If
0
(
Disable
) is displayed, parameter 11000
Set point sel
has been set to PID disabled.
If
1
(
PID
) is displayed, the controller is functioning and the drive speed reference is therefore linked to the PID out-
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......