ADV100 • Functions description and parameters list
133
PARAMETERS ON SELECTION LISTS, BUT NOT DISPLAYED ON KEYPAD
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
262
Motor speed nofilter
rpm INT16 16
0
0
0
ER
This parameter indicates the unfiltered motor speed.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
362
Drive overload trip
BIT
16
0
0
1
ER
This signal indicates that the drive is in the overload condition. In the default condition the alarm is not triggered as
the relative action is set to
Ignore
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
366
Drive overload 80
BIT
16
0
0
1
ER
This signal indicates that the drive has reached 80% of the thermal image accumulator (drive overload).
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
626
Ramp ref out mon
rpm INT16 16
0
0
0
ER
This parameter displays the reference value output of the ramp remference function block.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
760
Ramp out mon
rpm INT16 16
0
0
0
ER
This parameter displays the reference value output of the ramp function block.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
764
Ramp acc state
BIT
16
0
0
1
ER
This signal indicates whether the acceleration ramp is active.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
766
SRamp dec state
BIT
16
0
0
1
ER
This signal indicates whether the deceleration ramp is active.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
934
Ref is 0
BIT
16
0
0
1
ER
This signal is active when the reference is below the limit set in parameter
930 Reference 0 threshold
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
936
Ref is 0 delay
BIT
16
0
0
1
ER
This parameter is active when the reference is below the threshold set in parameter
930 Reference 0 threshold
.
The signal is enabled after the delay set with parameter
932 Reference delay 0
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
944
Speed is 0
BIT
16
0
0
1
ER
This parameter is active when the speed is below the threshold set in parameter
940 Speed 0 threshold
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
946
Speed is 0 delay
BIT
16
0
0
1
ER
This signal is active when the reference is below the threshold set in parameter
940 Speed 0 threshold
. The signal
is activated after the delay set in parameter
942 Speed 0 delay
.
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......