18
ADV100 • Functions description and parameters list
one and
Save parameters
.
After entering the password, press the E key once to enter it into the memory and again to enable it (= Enabled is
displayed to indicate that the password is enabled).
So that the password remains valid even after switching the unit off and then switching it back on, save it using the
Save parameters
command.
When the password is enabled any attempts to modify a parameter are blocked and the
Password enabled
mes-
sage is displayed.
To disable the password, enter the
Password
parameter (
572
) in the
DRIVE CONFIG
menu
.
Check that the password is enabled (
Enabled
), press
E
and enter the combination of figures that make up the pass-
word.
Press E again. A message is displayed telling you the password is no longer enabled (
Disabled
).
To make sure the password continues to be disabled even after switching the unit off and then switching it back on,
save this configuration using the
Save parameters
command.
When an incorrect password is entered, the Password wrong message is displayed
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
4.11
572
Application key
UINT32
0
0
4294967295 ERW
FVS
This parameter can be used to enter the key for enabling the PLC application.
You may need to enter a key to definitively enable some PLC applications. Please contact Gefran for details about
which PLC applications require the key.
If executing an application that envisages a key verification and the key is incorrect, enabling is forced for 200 hours
(time drive enabled).
In this phase a message is displayed informing you that the period of forced enabling time is about to expire.
At the first power-on after the 200 hours an alarm is generated and the application does not start.
Please contact Gefran for the numerical value of the key.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
4.12
574
Startup display
INT16
-1
-1
20000
ERW FVS
This is used to set the parameter that will be displayed automatically at drive power-on. Entering the value -1 (de-
fault), the function is disabled and the main menu is displayed at power-on.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
4.13
576
Display backlight
BIT
0
0
1
ERW FVS
Enabling of the backlight on the drive display.
If set to
0
the display backlight will go off when the drive has been on for three minutes.
If set to
1
the backlight will stay on for as long as the drive is powered.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
4.14
578
Language select
ENUM
English
0
9
RWZ FVS
Setting of the drive programming language.
0
English
1 Italian
2
French
3
German
4
Spanish
5
Polish
6
Romanian
7
Russian
8
Turkish
9
Portuguese
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......