46
ADV100 • Functions description and parameters list
In
Keypad
mode the drive is enabled if the hardware is enabled on the
Enable
terminal and the
Start
key is
pressed, with the
FastStop
command disabled.
In
Keypad
mode the drive is instantly disabled if there is no signal on the
Enable
terminal or the
Stop
key is pressed
twice, or if, when the speed=0 is reached, the terminal programmed as
FastStop
is enabled.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.4
1006 Speed 0 disable dly
ms
UINT16
1000
0
10000
ERW FVS
Setting of a delay in milliseconds between reaching the zero speed and disabling the drive when
Enable/Disable
mode
is set to a value other than
Off
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.5
1008 Stop key mode
ENUM
Inactive
0
1
ERW FVS
Setting of the stop key functioning on the keypad in case of Remote->Terminal or Remote->Digital or Local-
>Terminal mode. In Local -> Keypad mode this configuration is ineffective.
0
Inactive
1
EmgStop&Alarm
If the command is set to
Inactive
, pressing the Stop key on the keypad is ineffective.
If the command is set to
EmgStop&Alarm
, when the Stop key is pressed the motor stops in FastStop mode and the
Emg stop alarm
is generated. When the motor reaches the speed=0, the drive is automatically disabled and waits
for the
Fault reset
command. The
Fault reset
command must be sent twice to reset the drive.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.6
1010 Commands safe start
BIT
1
0
1
ERW FVS
This parameter is used to define whether the safe start command is disabled or enabled at drive power-on.
0
Off
1
On
If set to
Off
, the safe start command is disabled. If the drive is powered-on with the hardware enabled on the
Enable
terminal, the motor could start rotating.
When set to
On
, the safe start command is enabled. If the drive is powered-on with the hardware enabled on the
Enable
terminal, the motor will not rotate. To set the drive to accept subsequent commands, open the hardware
enabling contact on the
Enable
terminal and then close it again.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.7
1012 Dig local/remote
ENUM 16
Remote
0
1
ERW FVS
Setting
Local
or
Remote
operating mode.
0
Local
1
Remote
Writing this parameter is only effective if it is associated with
Local/Remote src
and if performed without the hard-
ware enabled on the
Enable
terminal. Press LOC to modify the value of this parameter 0<->1.
To disable the LOC key, set
Local/Remote src
to a value other than
Dig local/remote
.
Menu
PAR
Description
UM
Type
FB BIT
Def
Min
Max
Acc
Mod
11.8
1014 Local/remote src
LINK 16
1012
0
16384
ERW FVS
Selection of the origin (source) of the signal that switches between
Remote
and
Local
. Switching can only be per-
formed if the hardware is not enabled on the
Enable
terminal.
The signal to be associated with this function can be selected from the “
L_DIGSEL3
” selection list.
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......