ADV100 • Troubleshooting
151
Index
Error message
shown on the
display
Sub-code
Description
13
Plc 1
Reserved messages and dedicated to the PLC application. See the application manual.
14
Plc 2
15
Plc 3
16
Plc 4
17
Option bus fault
Condition:
this may occur when the drive is turned on, during fieldbus card setup. Error during configuration or communication error.
XXX0H-X
If the first digit to the left of “H” in the alarm sub-code is 0, the error regards a communication problem.
XXX0H-X
If the first digit to the left of “H” in the alarm sub-code is other than 0, the error regards a configuration problem.
Solution:
For configuration errors, check the configuration of the bus communication, type of bus, baudrate, address, parameter setting.
For communication errors, check wiring, termination resistors, disturbance immunity, timeout settings.
For further details, please refer to the user guide for the specific bus.
18
Key failed
Condition
: this may occur when powering the drive, if the incorrect enable key is inserted for a given firmware function.
0001H-1
Incorrect PLC key. PLC application not available.
Solution
: Ask Gefran to supply the correct key to enable the desired firmware function.
19
Key expiring
Condition:
this may occur at drive power-on if the incorrect enabling key was inserted for a given firmware function. At this stage the
firmware function can still be used freely, but this time limit is about to expire.
xxxxH-x
Number of hours for which the function can still be used freely.
Solution:
Ask Gefran for the correct key to enable the desired firmware function.
20
Param error
Condition
: if an error occurs during activation of the parameter database saved in flash; the alarm is inserted in the alarm list and alarm
log.
XXX0H-X
The code XXXXH-X indicates the IPA of the parameter that has been set outside the range allowed when the database is
enabled.
Solution
: Set the parameter causing the error to a value within the range and run
Save parameters
. Switch the drive off and then switch
it back on again.
If the IPA of the parameter is not shown in the manual, contact the service centre.
21
Encoder error
Condition:
this condition may occur when the drive is powered during encoder setup each time parameter
552 Regulation mode
is set.
100H-
2564
Cause
: An error occurred during setup; the information received from the encoder is not reliable. If the encoder is used for
feedback the
Speed fbk loss
[22] alarm is also generated.
Solution:
Take the recommended action for the
Speed fbk loss
[22] alarm.
200H-512 Cause
: The firmware on the optional encoder card is incompatible with that on the regulation card. The information received
from the encoder is not reliable
Solution
: Contact Gefran in order to update the firmware on the optional encoder card.
22
Options cfg
changed
Condition
: this may occur when powering the drive if an expansion card has been removed or replaced or the incorrect enable key is
inserted for a given firmware function.
0064H-
100
Card removed from slot 1
0014H-20
Card removed from slot 2
0003H-3
0078H-
120
Card removed from slot 1 and from slot 2
0067H-
103
0017H-23
007BH-
123
Solution
: Check the hardware configuration, then press ESC. Save the parameters (
Save parameters
, menu 04.01 par 550) to save the
new hardware configuration.
Note!
For any messages that are displayed but not included in this list reference should be made to the manual for the applica-
tion used by the drive.
Summary of Contents for SIEIDrive ADV100
Page 1: ... Functions description and parameters list SIEIDrive Field oriented vector AC Drive ADV100 ...
Page 28: ...28 ADV100 Functions description and parameters list Ramp freeze Ramp Output Motor speed ...
Page 152: ...152 ADV100 Block Diagrams F Block Diagrams System Diagrams Index Drive overview ...
Page 153: ...ADV100 Block Diagrams 153 References ...
Page 154: ...154 ADV100 Block Diagrams Ramps Braking ...
Page 155: ...ADV100 Block Diagrams 155 Multireference ...
Page 156: ...156 ADV100 Block Diagrams Motorpotentiometer Jog function ...
Page 157: ...ADV100 Block Diagrams 157 Monitor function ...
Page 158: ...158 ADV100 Block Diagrams ...
Page 159: ...ADV100 Block Diagrams 159 Commands ...
Page 160: ...160 ADV100 Block Diagrams ...
Page 161: ...ADV100 Block Diagrams 161 Digital inputs Digital outputs ...
Page 162: ...162 ADV100 Block Diagrams Analog inputs ...
Page 163: ...ADV100 Block Diagrams 163 Analog outputs Encoder config ...
Page 164: ...164 ADV100 Block Diagrams Speed reg gains ...
Page 165: ...ADV100 Block Diagrams 165 Torque config ...
Page 166: ...166 ADV100 Block Diagrams VF parameters ...
Page 167: ...ADV100 Block Diagrams 167 Functions ...
Page 168: ...168 ADV100 Block Diagrams ...
Page 169: ...ADV100 Block Diagrams 169 ...
Page 170: ...170 ADV100 Block Diagrams PID application ...
Page 171: ......