2-16
Data subject to change without notice 7/07. © 2007 GE Drives
(2) Control circuit terminals
30A
Y5A CMY
Y3
Y1
C1
FMA FMP PLC
X1
X2
X3
X4
X5
X6
X7
X8
X9
30C
30B Y5C
Y4
Y2
11
12
13
V2
CM
CM FWD REV P24
P24
DX- DX+
SD
2.3.5 AF-300 P11 Drive Cable Size, Tightening Torque and Circuit Protection Rating
Incoming Device
Tightening Torque lb-Inch (Nm)
Cable size AWG
Input Fuse
L1/R, L2/S, L3/T
(Nominal)
L1/R, L2/S, L3/T
(Maximum) (*1)
Auxiliary
Input
R0, T0
230 VAC Input
0.25
3
3
3
15
10.6 (1.2)
10.6
-
6.2 (0.7)
16
16
-
22
0.5
5
6
3
15
(1.2)
-
-
1
10
15
3
20
-
-
2
15
20
3
30
20.8 (2.36)
20.8
10.6 (1.2)
14
3
20
30
3
40
(2.36)
14
14
5
35
50
3
60
10
7.5
60
80
3
100
31.0 (3.5)
31.0
8
10
70
125
3
125
(3.5)
6
15
100
150
3
175
4
20
125
200
3
225
3
25
150
225
3
250
2
30
175
250
3
300
1
40
200
-
5
200
4/0
1/0
2/0
10
50
225
-
5
225
Qty2 - 1
3/0
4/0
10
60
300
-
5
300
239(27)
119(13.5)
119
Qty2 - 2/0
4/0
Qty2 - 1
75
350
-
5
350
(13.5)
Qty2 - 3/0
Qty2 - 1/0
Qty2 - 2/0
8
100
300
-
5
300
Qty 2 - 2/0
Qty2 - 3/0
Qty2 - 4/0
6
125
400
-
5
400
425(48)
239(27)
Qty2 - 4/0
Qty2 - 4/0
Qty2 - 250
4
150
450
-
5
450
Qty2 - 250
Qty2 - 300
Qty2 - 350
460 VAC Input
0.5
3
3
3
15
10.6 (1.2)
10.6
-
6.2 (0.7)
16
16
-
22
1
5
6
3
15
(1.2)
-
-
2
10
10
3
15
20.8 (2.36)
20.8
10.6 (1.2)
14
3
15
15
3
20
(2.36)
5
20
25
3
35
14
14
7.5
30
45
3
50
31.0 (3.5)
31.0
12
10
40
60
3
70
(3.5)
10
15
50
90
3
90
20
70
110
3
110
8
25
80
125
3
150
6
30
100
125
3
175
4
40
100
-
10
100
119(13.5)
2
3
3
10
50
125
-
10
125
1
2
2
60
150
-
10
150
51.3
2/0
2
1
75
175
-
10
175
(5.8)
3/0
1/0
2/0
100
150
-
10
150
2/0
3/0
4/0
125
200
-
10
200
239(27)
119(13.5)
3/0
4/0
Qty2 - 1
10
150
225
-
10
225
239(27)
119
Qty2 - 1/0
Qty2 - 1/0
Qty2 - 1/0
8
200
300
-
10
300
(13.5)
Qty2 - 1/0
Qty2 - 2/0
Qty2 - 3/0
250
400
-
10
400
425(48)
239
Qty2 - 3/0
Qty2 - 3/0
Qty2 - 4/0
6
300
450
-
10
450
(27)
Qty2 - 4/0
Qty2 - 250
Qty2 - 300
4
350
500
-
10
500
Qty2 - 250
Qty2 - 300
Qty2 - 350
400
600
-
10
600
(*3)
Qty2 - 350
Qty2 - 350
Qty2 - 500
(*3)
450
700
-
10
700
Qty2 - 350
Qty2 - 400
Qty2 - 500
500
700
-
10
700
Qty2 - 500
Qty3 - 300
Qty3 - 300
600
1000
-
10
1000
Qty3 - 300
Qty3 - 350
Qty3 - 500
700
1000
-
10
1000
Qty3 - 400
Qty3 - 500
Qty3 - 600
800
1200
-
10
1200
Qty3 - 500
Qty3 - 600
Qty3 - 600
(*1)Class J Fuse or Circuit Breaker reted 600V with the maximum current rating as shown in the above table shall be connected to the drive for 30HP and less.
(*2)Based on GE Fuji standard DB unit and DB resistor designs. Other rating require careful review.
(*3) Consult factory
Device ratings such as system coordination, short-circuit rating and type must be carefully reviewed by the user.
Wire size from NEC tables 310-16. Copper wire rated 60 Deg. C for 100amps or less, 75 Deg. C for over 100 amps in 30 Deg. C ambient and 1.25 times Drive rated amps.
These are minimum wire sizes : consult and conform to local and national codes.
Control
U, V, W
DC Reactor
P1, P(+)
DB circuit
(*2) P(+),
N(-), DB
R0,
T0
DB circuit
(*2) P(+),
N(-), DB
R0, T0
Control
L1/R, L2/S,
L3/T
51.3 (5.8)
119(13.5)
51.3 (5.8)
HP
Input Circuit
Breaker (*1)
L1/R, L2/S,
L3/T, U, V,
W, P1, P(+)
E(G)
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...