2-17
Data subject to change without notice 7/07. © 2007 GE Drives
2.3.6 DC Link Reactor
Dimensions in inches
Terminal
Width
Depth
Height
Note:
• AF-300 P11 Drives rated 100 Hp and above are furnished with a DC link reactor. This reactor must be installed
between terminal P1 and P+ prior to commissioning of the Drive.
• The weight of the DC Link Reactor is not included with that of the Drive.
• DC Link Reactor is provided as open type and is separately mounted. Enclosure to be provided by others.
Hp
Model No.
Width
Depth
Height
Weight
Loss [W]
230V P11
100
DCR2-75B
7.87
10.63
7.09
37
55
125
DCR2-90B
7.09
11.02
8.46
37
57
150
DCR2-110B
7.48
12.99
9.05
46
67
460V P11
100
DCR4-75B
7.48
10.63
6.89
35
58
125
DCR4-90B
7.48
11.02
7.87
44
64
150
DCR4-110B
7.48
11.02
7.87
46
73
200
DCR4-132B
7.87
11.02
8.07
55
84
250
DCR4-160B
8.27
12.6
8.07
68
90
300
DCR4-200B
8.27
12.99
9.06
75
126
350
DCR4-220B
8.66
13.78
9.06
81
131
400
DCR4-280B
8.66
14.57
9.65
95
133
450
DCR4-280B
8.66
14.57
9.65
95
150
500
DCR4-355B
9.84
12.99
8.78
99
205
600
DCR4-400B
9.84
13.78
9.17
106
215
700
DCR4-450B
10.63
13.78
10.35
121
272
800
DCR4-500B
11.1
14.17
10.35
143
292
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...