5-3
Func.
Factory Setting
Data
Change
No.
Setting Range
Unit
Min.
30 HP
40 HP
Format
during op
C20
JOG frequency
C20
JOG Hz
0.00 to 120.00 Hz
Hz
0.01
5.00
5
Y
C21
PATTERN
(mode select)
C21
PATTERN
0,1,2
-
-
0
1
operation
C22
(Stage 1)
C22
STAGE 1
Operation time: 0.00 to 6000 s
s
0.01
0.00 F1
13
C23
(Stage 2)
C23
STAGE 2
F1 to F4 and R1 to R4
0.00 F1
13
C24
(Stage 3)
C24
STAGE 3
0.00 F1
13
C25
(Stage 4)
C25
STAGE 4
0.00 F1
13
C26
(Stage 5)
C26
STAGE 5
0.00 F1
13
C27
(Stage 6)
C27
STAGE 6
0.00 F1
13
C28
(Stage 7)
C28
STAGE 7
0.00 F1
13
C30
Frequency command 2
C30
FREQ CMD 2
0 to 11
-
-
2
1
N
C31
Offset adjust
(terminal [12])
C31
BIAS 12
-100.0 to +100.0%
%
0.1
0.0
4
Y
C32
(terminal [C1])
C32
GAIN 12
0.0 to +200.0%
%
0.1
100.0
3
Y
5-31
C33
Analog setting signal filter
C33
REF FILTER
0.00 to 5.00s
s
0.01
0.05
5
Y
P:Motor Parameters
P01
Number of motor 1 poles
P01
M1 POLES
2 to 14
-
2
4
9
N
P02
Motor 1
(capacity)
P02
M1-CAP
Up to 30 HP: 0.01 to 60 HP
Hp
0.01
motor capacity
5
40 HP and above: 0.01 to 800 HP
P03
(rated current)
P03
M1-Ir
0.00 to 2000 A
A
0.01
motor rated current
19
N
P04
(tuning)
P04
M1 TUN1
0, 1, 2
-
-
0
21
N
P05
(on-line tuning)
P05
M1 TUN2
0, 1
-
-
0
1
N
P06
(no-load current)
P06
M1-Io
0.00 to 2000 A
A
0.01
standard rated value
19
N
P07
(%R1 setting)
P07
M1-%R1
0.00 to 50.00%
%
0.01
standard rated value
5
Y
P08
(%X setting)
P08
M1-%X
0.00 to 50.00%
%
0.01
standard rated value
5
Y
P09
Slip compensation control
P09
SLIP COMP1
0.00 to 15.00 Hz
Hz
0.01
0.00
5
Y
H:High Performance Functions
H03
Data initializing
H03
DATA INIT
0, 1
-
-
0
1
N
H04
Auto-reset
(times)
H04
AUTO-RESET
0, 1 to 10 times
-
1
0
1
Y
H05
(reset interval)
H05
RESET INT
2 to 20 s
s
1
5
1
Y
H06
Fan stop operation
H06
FAN STOP
0, 1
-
-
0
1
Y
H07
ACC/DEC pattern (mode select)
H07
ACC PTN
0,1,2,3
-
-
0
1
N
H08
Rev. phase sequence lock
H08
REV LOCK
0, 1
-
-
0
1
N
H09
Start mode
H09
START MODE
0, 1, 2
-
--
0
1
N
H10
Energy-saving operation
H10
ENERGY SAV
0, 1
-
-
1
1
Y
H11
DEC mode
H11
DEC MODE
0, 1
-
-
0
1
Y
H12
Instantaneous OC limiting
H12
INST CL
0, 1
-
-
1
1
N
H13
Auto-restart
(restart time)
H13
RESTART t
0.1 to 10.0 s
s
0.1
0.1
0.5
3
N
H14
(freq. fall rate)
H14
FALL RATE
0.00 to 100.00 Hz/s
Hz/s
0.01
10.00
5
H15
(holding DC voltage)
H15
HOLD V
3-phase, 230V class: 200 to 300V
V
1
200V class: 235V
1
3-phase, 460V class: 400 to 600V
400V class: 470V
H16
(OPR command self hold time)
H16
SELFHOLD t
0.0 to 30.0 s, 999
s
0.1
999
3
N
H19
Active drive
H19
AUT RED
0, 1
-
-
0
1
Y
H20
PID control
(mode select)
H20
PID MODE
0, 1, 2
--
-
0
1
N
5-38
H21
(feedback signal)
H21
FB SIGNAL
0, 1, 2, 3
-
-
1
1
N
H22
(P-gain)
H22
P-GAIN
0.01 to 10.00 times
-
0.01
0.1
5
Y
H23
(I-gain)
H23
I-GAIN
0.0, 0.1 to 3600 s
s
0.1
0.0
3
Y
H24
(D-gain)
H24
D-GAIN
0.00 s , 0.01 to 10.0 s
s
0.01
0.00
5
Y
H25
(feedback filter)
H25
FB FILTER
0.0 to 60.0 s
s
0.1
0.5
3
Y
H26
PTC thermistor
(mode select)
H26
PTC MODE
0, 1
0
1
Y
H27
(level)
H27
PTC LEVEL
0.00 to 5.00V
V
0.01
1.60
5
Y
H30
Serial link
(function select)
H30
LINK FUNC
0, 1, 2, 3
-
-
0
1
Y
H31
Modbus-RTU
(address)
H31
ADDRESS
0 (broadcast), 1 to 247
-
1
1
1
N
H32
(mode select on no response error)
H32
MODE ON ER
0, 1, 2, 3
-
-
0
1
Y
H33
(timer)
H33
TIMER
0.0 to 60.0 s
s
-
2.0
3
Y
H34
(baud rate)
H34
BAUD RATE
0, 1, 2, 3
-
-
1
1
Y
H35
(data length)
H35
LENGTH
0 (8-bit fixed)
-
-
0
1
Y
H36
(parity check)
H36
PARITY
0, 1, 2
-
-
0
1
Y
H37
(stop bits)
H37
STOP BITS
0 (2-bit), 1(1-bit)
-
-
0
1
Y
H38
(no response error detection time)
H38
NO RES t
0 (no detection), 1 to 60 s
s
1
0
1
Y
H39
(response interval)
H39
INTERVAL
0.00 to 1.00 s
s
0.01
0.01
5
Y
5-42
5-43
5-39/40
Pg.
5-29
5-29/30
5-30
5-37
5-41
Name
LCD Display
N
N
Y
Y
5-36
5-32
5-33
5-34
5-35
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...