12-3
Data subject to change without notice 7/07. © 2007 GE Drives
Monitoring parameter registers
Address Code
Description
Unit
Range
Min. unit
Read
Data
/ Write
Format
2049
M01
Frequency command (final
command)
-
- 20000–20000 (max. frequency
at ± 20000)
1
R
2
2053
M05
Frequency command (final
command)
Hz
0–400.00 0.01
R
5
2054
M06
Actual frequency
-
- 20000–20000
1
R
2
(max. frequency at ± 20000)
2055
M07
Actual torque value
%
- 200.00–200.00
0.01
R
6
2056
M08
Torque current
%
- 200.00–200.00
0.01
R
6
2057
M09
Output frequency
Hz
0.00–400.00
0.01
R
5
2058
M10
Motor output (input
electric power)
%
0.00–200.00
0.01
R
5
2059
M11
Output current r. m. s.
%
0.00–200.00 (inverter rating at
100.00)
0.01
R
5
2060
M12
Output voltage r. m. s.
V
0.0–600.0
1
R
3
2061
M13
Operation command (final
command)
-
Refer to data format [14]
-
R
14
2062
M14
Operating state
-
Refer to data format [16]
-
R
16
2063
M15
Universal output terminal
data
-
Refer to data format [15]
-
R
15
2064
M16
Fault memory 0
-
Refer to data format [10]
-
R
10
2065
M17
Fault memory 1
-
10
2066
M18
Fault memory 2
-
10
2067
M19
Fault memory 3
-
10
2068
M20
Integrated operating time
h
0–65535
1
R
1
2069
M21
DC link voltage
V
0–1000
1
R
1
2071
M23
Type code
-
Refer to data format [17]
-
R
17
2072
M24
Drive capacity code
-
Refer to data format [11]
-
R
11
2073
M25
ROM version
-
0–64999
1
R
1
2074
M26
Transmission error
processing code
-
Refer to data format [20]
-
R
20
2075
M27
Frequency command at
alarm (final command)
-
- 20000–20000 (max. frequency
at ±20000 )
1
R
2
2079
M31
Frequency command at
alarm (final command)
Hz
0–400.00 0.01
R
5
2080
M32
Actual frequency at alarm
-
- 20000–20000
1
R
2
(max. frequency a t ± 20000)
2081
M33
Actual torque at alarm
%
- 200.00 – 200.00
0.01
R
6
2082
M34
Torque current at alarm
%
- 200.00 – 200.00
0.01
R
6
2083
M35
Output frequency at alarm
Hz
0.00 – 400.
0.01
R
5
2084
M36
Motor output at alarm
(input power)
%
0.00–200.00
0.01
R
5
2085
M37
Output current r.m.s. at
alarm
%
0.00 – 200.00 (inverter rating at
100.00)
0.01
R
5
2086
M38
Output voltage effective
value at alarm
V
0.0 – 600.0
1
R
3
2087
M39
Operation command at
alarm
-
Refer to data format [14]
-
R
14
2088
M40
Operating state at alarm
-
Refer to data format [16]
-
R
16
2089
M41
Universal output terminal
data at alarm
-
Refer to data format [15]
-
R
15
2090
M42
Integrated operation time
at alarm
h
0–65535
1
R
1
2091
M43
DC link voltage at alarm
V
0–1000
1
R
1
2092
M44
Inverter internal air temp.
at alarm
°C
0–120
1
R
1
2093
M45
Cooling fin temp. at alarm
°C
0–120
1
R
1
2094
M46
Life of main circuit
capacitor.
%
0.0–100.0
0.1
R
3
2095
M47
Life of printed circuit
board capacitor.
h
0–65535
1
R
1
2096
M48
Life of cooling fan.
h
0–65535
1
R
1
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...