5-2
E: Terminal Extensions Functions
Pg.
Func.
Factory Setting
Data
Change
No.
Setting Range
Unit
Min.
30 HP
40 HP
Format
During op
E01
X1 terminal function
E01
X1 FUNC
0 to 32
0
1
N
E02
X2 terminal function
E02
X2 FUNC
1
1
N
E03
X3 terminal function
E03
X3 FUNC
2
1
N
E04
X4 terminal function
E04
X4 FUNC
3
1
N
E05
X5 terminal function
E05
X5 FUNC
-
-
4
1
N
E06
X6 terminal function
E06
X6 FUNC
5
1
N
E07
X7 terminal function
E07
X7 FUNC
6
1
N
E08
X8 terminal function
E08
X8 FUNC
7
1
N
E09
X9 terminal function
E09
X9 FUNC
8
1
N
E10
Acceleration time 2
E10
ACC TIME2
0.01 to 3600 s
s
0.01
6.00
20.00
12
Y
E11
Deceleration time 2
E11
DEC TIME2
6.00
20.00
12
Y
E12
Acceleration time 3
E12
ACC TIME3
6.00
20.00
12
Y
E13
Deceleration time 3
E13
DEC TIME3
6.00
20.00
12
Y
E14
Acceleration time 4
E14
ACC TIME4
6.00
20.00
12
Y
E15
Deceleration time 4
E15
DEC TIME4
6.00
20.00
12
Y
E16
Torque limiter 2
(driving)
E16
DRV TRQ 2
20 to 150%, 999
%
1
999
1
Y
E17
(braking)
E17
BRK TRQ 2
0%, 20 to 150%, 999
%
1
999
1
Y
E20
Y1 terminal function
E20
Y1 FUNC
0 to 33
0
1
N
E21
Y2 terminal function
E21
Y2 FUNC
1
1
N
E22
Y3 terminal function
E22
Y3 FUNC
-
-
2
1
N
E23
Y4 terminal function
E23
Y4 FUNC
7
1
N
E24
Y5A, Y5C terminal function
E24
Y5 FUNC
10
1
N
5-24
E25
Y5 RY operation mode
E25
Y5RY MODE
0,1
-
1
0
1
N
E30
FAR function
(Hysteresis)
E30
FAR HYSTR
0.0 to 10.0 Hz
Hz
0.1
2.5
3
Y
E31
FDT function
(level)
E31
FDT1 LEVEL
0 to120 Hz
Hz
1
60
1
E32
signal
(Hysteresis)
E32
FDT1 HYSTR
0.0 to 30.0 Hz
Hz
0.1
1.0
3
E33
OL function
(mode select)
E33
OL1 WARNING
0: Thermal calculation
-
-
0
1
1: Output current
E34
signal (L
(level)
E34
OL1 LEVEL
5 to 150% of rated drive current
A
0.01
motor rated current
19
E35
(timer)
E35
OL1 TIMER
0.1 to 60.0 s
s
0.1
10.0
3
E36
FDT2 function
(level)
E36
FDT2 LEVEL
0 to 120 Hz
Hz
1
60
1
E37
OL2 function
(level)
E37
OL2 LEVEL
5 to 150% of rated drive current
A
0.01
motor rated current
19
E40
Display coefficient A
E40
COEF A
-999.00 to 999.00
-
0.01
0.01
12
E41
Display coefficient B
E41
COEF B
-999.00 to 999.00
-
0.01
0.00
12
Y
E42
LED Display filter
E42
DISPLAY FL
0.0 to 5.0 s
s
0.1
0.5
3
Y
E43
LED Monitor
(function)
E43
LED MNTR
0 to 12
-
-
0
1
Y
E44
(display in STOP mode)
E44
LED MNTR2
0, 1
-
-
0
1
Y
E45
LCD Monitor
(function)
E45
LCD MNTR
0, 1
-
-
0
1
Y
E46
(language)
E46
LANGUAGE
0 to 5
-
-
1
1
Y
E47
(contrast)
E47
CONTRAST
0(soft) to 10(hard)
-
-
5
1
Y
C:Frequency Control Functions
C01
Jump
(Jump freq. 1)
C01
JUMP Hz 1
0 to 120 Hz
Hz
1
0
1
C02
frequency
(Jump freq. 2)
C02
JUMP Hz 2
0
1
C03
(Jump freq. 3)
C03
JUMP Hz 3
0
1
C04
(Hysteresis)
C04
JUMP HYSTR
0 to 30 Hz
Hz
1
3
1
C05
Multistep
(Freq. 1)
C05
MULTI Hz-1
0.00 to 120.00 Hz
Hz
0.01
0.00
5
C06
frequency
(Freq. 2)
C06
MULTI Hz-2
0.00
5
C07
setting
(Freq. 3)
C07
MULTI Hz-3
0.00
5
C08
(Freq. 4)
C08
MULTI Hz-4
0.00
5
C09
(Freq. 5)
C09
MULTI Hz-5
0.00
5
C10
(Freq. 6)
C10
MULTI Hz-6
0.00
5
C11
(Freq. 7)
C11
MULTI Hz-7
0.00
5
C12
(Freq. 8)
C12
MULTI Hz-8
0.00
5
C13
(Freq. 9)
C13
MULTI Hz-9
0.00
5
C14
(Freq. 10)
C14
MULTI Hz-10
0.00
5
C15
(Freq. 11)
C15
MULTI Hz-11
0.00
5
C16
(Freq. 12)
C16
MULTI Hz-12
0.00
5
C17
(Freq. 13)
C17
MULTI Hz-13
0.00
5
C18
(Freq. 14)
C18
MULTI Hz-14
0.00
5
C19
(Freq. 15)
C19
MULTI Hz-15
0.00
5
Y
Y
Y
Name
LCD Display
Y
Y
5-26
5-27
5-28
5-18/21
5-22
5-22/24
5-25
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...