The keypad panel has various functions for specifying operations such as frequency setting, run/stop command, confirm-
ing and changing function data, confirming status, and copying function code settings.
Review the use of each function before attempting to operate the drive from the keypad panel.
The keypad panel can also be removed or inserted during inverter operation. However, if the keypad panel is removed
during keypad panel operation (e.g., run/stop, frequency setting), the drive stops and outputs an alarm.
Control keys
(valid during keypad panel operation):
Used for drive run and stop
FWD
Forward operation command
REV
Reverse operation
STOP
Stop command
Operation keys:
Used for switching screens, data
change,frequency setting, etc.
4.1 Appearance of Keypad Panel
Operation Keys
Primary Function
PRG
Used to switch the current screen to the menu screen or switch to the initial screen in operation / trip mode.
FUNC
DATA
Used to switch the LED monitor or to determine the entered frequency, function code, or data
Used to change data, move the cursor up or down, or scroll the screen
SHIFT
Used to move the cursor horizontally at data change. When this key is pressed with the up or down key, the cursor moves to
the next function block.
RESET
Used to cancel current input data and switch the displayed screen. If an alarm occurs, this key is used to reset the trip status
(valid only when the initial alarm mode screen is displayed)
STOP
+
Used to switch normal operation mode to jogging operation mode or vice versa. The selected mode is displayed on the LCD
monitor.
STOP
+
RESET
Switches operation mode (from keypad panel operation mode to terminal block operation mode or reverse). When these keys
are operated, function F02 data is switched from 0 to 3 or from 1-4 to 0. The selected mode is displayed on the LCD
indicator.
4. Keypad Panel
LED monitor
4-digit display. Used to display data such as setting frequency, output
frequency and alarm code.
Auxiliary Information Related to LED Monitor
Indicates selected units or multiple of the data shown on the LED monitor
and is displayed on the top line of the LCD monitor. The
■
symbol
indicates selected units or multiple number. The symbol indicates that
there is an upper screen not currently displayed.
LCD Monitor:
Used to display various items of information such as operation status and
function data. An operating guide message, is scrolled and displayed at
the bottom of the LCD monitor. This LCD monitor has a backlight feature
which turns on when the control power is applied or any keypad key is
pressed, and stays on approximately 5 minutes after the last key stroke.
Status Indicators on LCD Monitor:
Displays current operating status:
FWD: Forward operation
REV: Reverse operation
STOP: Stop
Displays the selected operating mode:
REM: terminal block
LOC: keypad panel
COMM: communication terminal
JOG: jogging mode
The symbol
indicates that there is a lower screen not currently displayed.
RUN LED (valid during operation from keypad panel):
Indicates that an operation command was input by pressing the FWD or
REV key.
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...