8-4
Data subject to change without notice 7/07. © 2007 GE Drives
8.3 Main Circuit Measurements
The indicated values depend on the type of meter, because the harmonic component is included in the voltage and
current of the main circuit power (input) and the output (motor) side of the inverter. If measuring with a meter for commer-
cial power frequency use, use the meters shown in Table 8.3.1.
The power factor cannot be measured using power factor meters currently available on the market, which measure the
phase difference between voltage and current. If power factors must be measured, measure the power, voltage, and
current on the input side and output side, then calculate the power factor using the following formula:
Table 8.3-. Meters for Measuring Main Circuit
I
tem
Input (power supply) Side
Output (motor) Side
DC Link Circuit
Voltage
P(+) - N(-)
Voltage Current
Voltage Current
Meter name
Ammeter
Voltmeter
Powermeter
Ammeter
Voltmeter
Powermeter
DC Voltmeter
AR,S,T
VR,S,T
WR,S,T
AU,V,W
VU,V,W
WU,V,W
V
Meter type
Moving iron
Rectifier or
Digital
Moving iron
Rectifier
Digital power
Moving coil type
type
moving-iron power meter
type
type
meter
type
Symbol
Note:
If the output voltage is measured with a rectifier type meter, an error may occur. Use a digital AC power meter to
ensure accuracy.
Power factor =
Power [W]
x 100 [%]
3 x Voltage [V] x Current [A]
Summary of Contents for AF-300 P11
Page 1: ...GE Consumer Industrial AF 300 P11 User s Guide ...
Page 35: ...2 18 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 37: ...3 2 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 53: ...4 16 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 62: ...5 9 Frequency Setting Block Diagram ...
Page 66: ...5 13 ...
Page 84: ...5 31 Notes ...
Page 99: ...5 46 Notes ...
Page 109: ...7 8 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 115: ...8 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...
Page 123: ...10 6 Data subject to change without notice 7 07 2007 GE Drives Notes ...