Power supply
6.2
Converting a standard power supply to a
redundant power supply
The standard power supply can be replaced by a redundant power supply. The
redundant power supply consists of up to two PSU modules. The upgrade kit
contains only one PSUmodule (for power supply redundancy the second PSU
module must be additionally ordered).
The upgrade kit for the redundant power supply consists of the following parts:
– PSU cage with power distribution board (incl.power cables)
– one PSU module
– dummy cover (if only one power supply module is installed, you have to
install the dummy cover in the second bay)
– several screws
6.2.1
Required tools
●
Preliminary and concluding steps: tool-less
●
Converting a standard power supply to a redundant power supply:
– Phillips PH2 / (+) No. 2 screw driver
Field Replaceable Units (FRU)
Average task duration: 10 minutes
Summary of Contents for PRIMERGY TX140 S1
Page 6: ...Upgrade and Maintenance Manual TX140 S1 ...
Page 22: ...Upgrade and Maintenance Manual TX140 S1 Contents ...
Page 24: ...24 Upgrade and Maintenance Manual TX140 S1 ...
Page 40: ...40 Upgrade and Maintenance Manual TX140 S1 Before you start ...
Page 204: ...204 Upgrade and Maintenance Manual TX140 S1 Hard disk drives solid state drives ...
Page 292: ...292 Upgrade and Maintenance Manual TX140 S1 Expansion cards and backup units ...
Page 306: ...306 Upgrade and Maintenance Manual TX140 S1 Main memory ...
Page 370: ...370 Upgrade and Maintenance Manual TX140 S1 Accessible drives ...
Page 414: ...414 Upgrade and Maintenance Manual TX140 S1 Front panel and external connectors ...
Page 472: ...472 Upgrade and Maintenance Manual TX140 S1 System board and components ...
Page 568: ...568 Upgrade and Maintenance Manual TX140 S1 Cabling ...