1. Standard Specifications
1. Standard Specifications
1.1 Three-phase 230V FRENIC5000G11S Series
Item
Specifications
Type
FRN
■■■
■■■
G11S-2UX
F25 F50 001 002 003 005 007 010 015 020 025 030
040 050 060 075 100 125
Nominal applied motor
HP
1/4
1/2
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100 125
Rated capacity *1)
kVA
0.6
1.2
2.0
3.2
4.4
6.8
9.9
13
18
23
29
36
46
58
72
86
113 138
Rated voltage *2)
V
3-phase 200V/50Hz 200, 220, 230V/60Hz
Output
Rated current *3)
A
1.5
3.0
5.0
8.0
11
17
25
33
46
59
74
87
115 145 180 215 283 346
ratings
Overload capability
150% of rated current for 1min.
150% of rated current for 1min.
200% of rated current for 0.5s
180% of rated current for 0.5s
Rated frequency
Hz
50, 60Hz
Phases, Voltage, Frequency
3-phase 200 to 230V 50/60Hz
3-phase 200 to 220V/50Hz (220 to 230V/50Hz) *11)
200 to 230V/60Hz
Voltage / frequency variations
Voltage : +10 to –15% (Voltage unbalance *4) : 2% or less) Frequency :+5 to –5%
Momentary voltage dip capability
When the input voltage is 165V or more, the inverter can be operated continuously.
Input
*5)
When the input voltage drops below 165V from rated voltage, the inverter can be operated for 15ms .
ratings
The smooth recovery method is selectable.
Rated current *6) (with DCR)
0.94 1.6
3.1
5.7
8.3 14.0 19.7 26.9 39.0 54.0 66.2 78.8 109 135 163 199 272 327
A (without DCR)
1.8
3.4
6.4 11.1 16.1 25.5 40.8 52.6 76.9 98.5 117 136
168 204 243 291
-
-
Required power supply
capacity *7)
kVA
0.4
0.6
1.1
2.0
2.9
4.9
6.9
9.4
14
19
23
28
38
47
57
69
95
114
Maximum frequency
50 to 400Hz
Setting
Base frequency
25 to 400Hz
Starting frequency
0.1 to 60Hz, Holding time: 0.0 to 10.0s
Carrier frequency
*8)
0.75 to15kHz
0.75 to 10kHz
Output
Accuracy (Stability)
• Analog setting :
±
0.2% of Maximum frequency (at 25
±
10
°
C (77
±
50
°
F))
frequency
• Digital setting :
±
0.01% of Maximum frequency (at –10 to +50
°
C (14 to 122
°
F))
Setting resolution
• Analog setting : 1/3000 of Maximum frequency ex.) 0.02Hz at 60Hz, 0.04Hz at 120Hz, 0.15Hz at 400Hz
• Digital setting :
0.01Hz at Maximum frequency of up to 99.99Hz (0.1Hz at Maximum frequency of 100Hz and above)
• LINK setting
: Selects from the following two items.
• 1/20000 of Maximum frequency ex.) 0.003Hz at 60Hz, 0.006Hz at 120Hz, 0.02Hz at 400Hz
• 0.01Hz (Fixed)
Voltage / freq. (V/f) characteristic
Adjustable at base and maximum frequency, with AVR control : 80 to 240V
Torque boost
Torque boost can be set, using Function code F09 and A05.
0.0
: Automatic (for constant torque load)
Control
0.1 to 0.9 : Manual (for variable torque load) *9)
1.0 to 1.9 : Manual (for propotional speed torque load)
2.0 to 20.0: Manual (for constant torque load)
Starting torque
200% (with Dynamic torque-vector control selected)
180% (with Dynamic torque-vector control selected)
Braking torque
*10)
150%
100%
20%
10 to 15%
Standard Time
s
10
5
5
No limit
Duty cycle
%ED
10
5
3
5
3
2
3
2
No
l
imit
Standard Braking torque
150%
100%
Using
Time
s
90
45
45
45
30
20
10
8
10
Braking
Duty cycle%ED
37
22
18
10
7
5
5
5
10
options 10%ED Braking torque
150%
*12)
Time
s
90
45
30
20
10
Duty cycle%ED
10
10
10
DC injection braking
Starting frequency: 0.1 to 60.0Hz Braking time: 0.0 to 30.0s Braking level: 0 to 100% of rated current
*Inverter restarts at the starting frequency when operation command is input while braking is operating.
*DC injection braking does not operate at the time of change-over from forward to reverse operation.
*DC injection braking does not operate when frequency setting is decreased while operation command (FWD, REV) is being input.
Enclosure (IEC 60529)
IP 40
IP 00 ( IP 20 : Option )
Cooling method
Natural cooling
Fan cooling
-UL/cUL -Low Voltage Directive
-EMC Directive
-TÜV (up to 30HP)
Standards
-IEC 61800-2 (Ratings, specifications for low voltage adjustable frequency a.c. power drive systems)
-IEC 61800-3 (EMC product standard including specific test methods)
Weight
lbs
4.9 4.9
5.5
8.4
8.4
8.4
13
13
22
22
23
23
64
79
97
101 154 254
(kg)
(2.2) (2.2) (2.5) (3.8) (3.8) (3.8) (6.1) (6.1) (10) (10) (10.5) (10.5) (29) (36) (44) (46) (70) (115)
NOTES: *1)
Inverter output capacity (kVA) at 230V. Rated capacity reduces when power supply voltage decreases.
*2)
Output voltage cannot exceed the power supply voltage.
*3)
Current derating may be required in case of low impedance loads such as high frequency motor.
*4)
Use a DC REACTOR (DCR) when the voltage unbalance exceeds 2%. (This value is equivalent to FUJI’s conventional allowable value.)
Voltage unbalance (%) = Max. voltage [V] – Min. Voltage [V] x 67
(Conforming to EN61800-3 (5.2.3))
Three-phase average voltage[V]
*5)
Tested at standard load condition (85% load).
*6)
This value is under FUJI original calculation method.
*7)
When power-factor correcting DC REACTOR (DCR) is used.
*8)
When inverter is operating at a carrier frequency of 10kHz or higher, the inverter may automatically reduce the carrier frequency to 8kHz for protecting inverter.
*9)
When torque boost is set at 0.1, starting torque of 50% or more can be obtained.
*10) With a nominal applied motor, this value is average torque when the motor decelerates and stops from 60Hz. (It may change according to motor loss.)
*11) Order individually.
*12) Applicable to 10%ED when using options (standard)
Chapter01J(P1˜5).p65
07.8.9, 19:10
Page 2
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......