1-13
Chapter 1
2. Common Specifications
1
The function marked can be set while the inverter is running. Other functions must be set while the inverter is
stopped.
Function
Setting range
Unit
Min.
Factory setting
Remarks
Code Name
LCD monitor
unit
30HP
40HP
13 : DC brake command
[DCBRK]
14 : Torque limiter 2 / Torque limiter 1
[TL2/TL1]
15 : Switching operation between line and inverter
(50Hz)
[SW50]
16 : Switching operation between line and inverter
(60Hz)
[SW60]
17 : UP command
[UP]
18 : DOWN command
[DOWN]
19 : Write enable for KEYPAD
[WE-KP]
20 : PID control cancel
[Hz/PID]
21 : Inverse mode changeover (terminals 12 and C1)
[IVS]
22 : Interlock signal for 52-2
[IL]
23 : TRQ control cancel
[Hz/TRQ]
24 : Link enable (Bus, RS-485)
[LE]
25 : Universal DI
[U-DI]
26 : Pick up start mode
[STM]
27 : SY-PG enable
[PG/Hz]
28 : Synchronization command
[SYC]
29 : Zero speed command
[ZERO]
30 : Forced stop command
[STOP1]
31 : Forced stop command with Deceleration time 4
[STOP2]
32 : Pre-exciting command
[EXITE]
E10
Acceleration time 2
E10
ACC TIME2
0.01 to 3600s
E11
Deceleration time 2
E11
DEC TIME2
E12
Acceleration time 3
E12
ACC TIME3
E13
Deceleration time 3
E13
DEC TIME3
E14
Acceleration time 4
E14
ACC TIME4
E15
Deceleration time 4
E15
DEC TIME4
E16
Torque limiter 2
(Driving)
E16
DRV TRQ 2
G11S: 20 to 200%, 999% (999: No limit) *2)
P11S : 20 to 150%, 999% (999: No limit)
E17
(Braking)
E17
BRK TRQ 2
G11S: 0 (Automatic deceleration control),
20 to 200%, 999% (999: No limit) *2)
P11S : 0 (Automatic deceleration control),
20 to 150%, 999% (999: No limit)
E20
Y1 terminal function
E20
Y1 FUNC
Selects from the following items.
E21
Y2 terminal function
E21
Y2 FUNC
E22
Y3 terminal function
E22
Y3 FUNC
E23
Y4 terminal function
E23
Y4 FUNC
E24
Y5A,Y5C terminal function
E24
Y5 FUNC
0 : Inverter running
[RUN]
1 : Frequency equivalence signal
[FAR]
2 : Frequency level detection
[FDT1]
3 : Undervoltage detection signal
[LU]
4 : Torque polarity
[B/D]
5 : Torque limiting
[TL]
6 : Auto-restarting
[IPF]
7 : Overload early warning
[OL1]
8 : KEYPAD operation mode
[KP]
9 : Inverter stopping
[STP]
10 : Ready output
[RDY]
11 : Line/Inv changeover (for 88)
[SW88]
12 : Line/Inv changeover (for 52-2)
[SW52-2]
13 : Line/Inv changeover (for 52-1)
[SW52-1]
(11 to 13: For Line/Inverter changeover operation)
14 : Motor 2 / Motor 1
[SWM2]
15 : Auxiliary terminal (for 52-1)
[AX]
16 : Time-up signal
[TU]
17 : Cycle completion signal
[TO]
18 : Stage No. indication 1
[STG1]
19 : Stage No. indication 2
[STG2]
20 : Stage No. indication 4
[STG4]
(16 to 20: For PATTERN operation)
21 : Alarm indication 1
[AL1]
22 : Alarm indication 2
[AL2]
23 : Alarm indication 4
[AL4]
24 : Alarm indication 8
[AL8]
(21 to 24: For Alarm signal output)
25 : Fan operation signal (for 40HP and above) [FAN]
26 : Auto-resetting
[TRY]
27 : Universal DO
[U-DO]
28 : Overheat early warning
[OH]
29 : Synchronization completion signal
[SY]
30 : Lifetime alarm
[LIFE]
31 : 2nd Freq. level detection
[FDT2]
32 : 2nd OL level early warning
[OL2]
33 : Terminal C1 off signal
[C1OFF]
34 : Speed existence signal
[DNZS]
E25
Y5 RY operation mode
E25
Y5RY MODE
0 : Inactive (Y5 Ry excites at "ON signal" mode.)
1 : Active (Y5 Ry excites at "OFF signal" mode.)
s
0.01
6.00
20.00
s
0.01
6.00
20.00
s
0.01
6.00
20.00
s
0.01
6.00
20.00
s
0.01
6.00
20.00
s
0.01
6.00
20.00
%
1
999
%
1
999
-
-
0
-
-
1
-
-
2
-
-
7
-
-
10
-
-
0
15, 16: When 15 or 16 is turned
on, the operation smoothly
changes to commercial
power operation at 50 or
60Hz, without stopping the
motor.
From 50Hz power line : (SW50)
From 60Hz power line : (SW60)
17, 18 : "F01" must be set at
"8: UP/DOWN
control 1" or "9: UP/
DOWN control 2".
20 :When this signal is on,
PID control is canceled
and KEYPAD operation
is effective.
23 :
When this signal is on,
torque control is canceled.
27 : PG/Hz is option.
28 : SY is option.
29 : ZERO is option.
32 : EXITE is option.
F07
F08
F40, F41
29 : SY is option.
34: DNZS is option.
Chapter01J(P6˜18).p65
07.8.9, 11:53
Page 13
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......