Chapter 6
2. FRENIC5000G11S/P11S Series
6-7
6
■
Function setting value (Recommended: G11S)
Other than the above functions, some of the basic functions such as base frequency, maximum frequency, acceleration/deceleration time, and
motor characteristics parameters should be set.
■
Tips
1. High torque in the low speed range
• The starting time can be reduced and the stopping accuracy
can be improved by reduced motor wow and high torque
output in the low speed range.
2. Improved response
• The starting time can be reduced and the stopping accuracy
can be improved by reduced motor wow and high torque
output in the low speed range.
• Because the response level has been improved, more
precise conveyance can be carried out even for highly
frequent operations.
3. Full preparation to suppress harmonics with a DC
REACTOR
• An exclusive terminal (P1, P(+)) for connecting a DC
REACTOR is equipped as standard.
• Connect the optional DC REACTOR (DCR - ) to
reduce harmonics on power supply side.
4. Suppression of inrush current when the power
supply is turned on
• FRENIC5000G11S series inverters have a built-in circuit that
suppresses inrush current that are generated when the
power supply is turned on. No measures have to be taken to
handle inrush current in particular.
5. Different motor capacities
• Please inquire if the difference in the capacities of motors 1
and 2 exceeds three frames.
Function
Name
Factory setting
Recommended setting value
Remarks
code
F10
Electronic thermal relay
for motor 1
(Select)
F11
(Level)
F12
(Thermal time constant)
F42
Torque vector control 1
P01
Motor 1
(No. of poles)
P02
(Capacity)
P03
(Rated current)
P04
(Tuning)
P05
(On-line tuning)
P06
(No-load current)
P07
(%R1 setting)
P08
(%X setting)
P09
(Slip compensation control)
A06
Electronic thermal relay
for motor 2
(Select)
A07
(Level)
A08
(Thermal time constant)
A09
Torque vector control 2
A10
Motor 2
(No. of poles)
A11
(Capacity)
A12
(Rated current)
A13
(Tuning)
A14
(On-line tuning)
A15
(No-load current)
A16
(%R1 setting)
A17
(%X setting)
A18
(Slip compensation
control)
E07
X7 terminal (Function select)
H06
Fan stop operation
F26
Motor sound
(Carrier freq.)
F14
Restart mode after
momentary power failure
(Mode select)
1: Active (Standard motor)
100% of motor rated current
5.0min (30HP or smaller)
10.0min (40HP or larger)
0: Inactive
4: 4-pole
Capacity of motor used
Fuji’s standard value
0: Inactive
0: Inactive
Fuji’s standard value
Fuji’s standard value
Fuji’s standard value
Fuji’s standard value
1: Active (Standard motor)
100% of motor rated current
5.0min (30HP or smaller)
10.0min (40HP or larger)
0: Inactive
4: 4-pole
Capacity of motor used
Fuji’s standard value
0: Inactive
0: Inactive
Fuji’s standard value
Fuji’s standard value
Fuji’s standard value
Fuji’s standard value
6:
3-wire operation stop command
0: Inactive
2: 2kHz
0: Inactive
(Trip and alarm when power
failure occurs.)
1: Active (Standard motor)
100% rated current of motor used
5.0min (30HP or smaller)
10.0min (40HP or larger)
1: Active
2 to 14: 2- to 14-pole
1/8 to 60HP: 30HP or smaller
1/8 to 800HP: 40HP or larger
0.00 to 2000A
1: Active
1: Active
0.00 to 2000A
0.00 to 50.00%
0.00 to 50.00%
0.00 to 5.00Hz
1: Active (Standard motor)
100% rated current of motor used
5.0min (30HP or smaller)
10.0min (40HP or larger)
1: Active
2 to 14: 2- to 14-pole
1/8 to 60HP: 30HP or smaller
1/8 to 800HP: 40HP or larger
0.00 to 2000A
1: Active
1: Active
0.00 to 2000A
0.00 to 50.00%
0.00 to 50.00%
0.00 to 5.00Hz
12: motor2/motor1
1: Active
15: 15kHz
10: 10kHz
0: Inactive
(Trip and alarm when power failure
occurs.)
Set if necessary.
Set according to the motor used.
Set according to be motor used
before tuning.
Set P04 first, and then P05.
Values are detected and written
automatically during tuning.
Set the value in accordance with
the equipment to be combined.
Set if necessary.
Set according to the motor used.
Set according to be motor used
before tuning.
Set A13 first, and then A14.
Values are detected and written
automatically during tuning.
Set the value in accordance with
the equipment to be combined.
For 75HP or smaller inverter.
For 100HP or larger inverter.
Set H13 to H16 also, if necessary.
Chapter6-3(P6˜7).p65
07.8.9, 12:51
Page 7
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......