Chapter 6
2. FRENIC5000G11S/P11S Series
6-20
Caution
The information described in this catalog is for the purpose of selecting the appropriate products.
Before actually using this product, be sure to read the instruction manual carefully to ensure proper
operation.
1. A Solution to growing demand for energy sav-
ings: Automatic energy saving operation
• Under the energy saving mode, conditions can be set
automatically to ensure that the motor runs at peak effi-
ciency. This approach takes into consideration the axial
force of fans which frequently changes. This results in
minimized power consumption, and satisfies the increasing
demand for the greater energy savings.
2. Automatic stopping of the inverter cooling fan
while air conditioning system is not in operation
• By selecting cooling fan stop operation, the inverter cooling
fan can be stopped when the temperature of the inverter
cooling fan becomes low while the inverter operation
command is off.
• Although energy savings may appear minimal from the point
of view of the air conditioning unit itself, the total saving
effect that can be realized by the whole air conditioning
system is significant. Furthermore, the cooling fan stop
operation contributes to a more quiet operation, as the
cooling fan operation sound may be a nuisance at night.
3. Unnecessary to resort to any special sound-
proofing measures; Fuji inverter drives a motor
with silent motor sound.
• We have succeeded in eliminating most of the unpleasant
motor sound that usually comes from the motor which is
driven by the inverter.
The sound levels are comparable to those of commercial
power sources.
■
Wiring diagram/System configuration
2.9 Using with Fans for Air Conditioning Unit (1)
■
Advantages
Sensor power
supply unit
Current output
(4 to 20mA)
(to the monitoring room)
(+)
(-)
Control power supply
Outlet
Outlet
Room temperature sensor
Damper
(fully opened)
Air conditioning
fan
Alarm output
(for any fault)
"Inverter running"
signal output
Output for inverter panel
cooling fan operation command
L1/R
L2/S
L3/T
13
12
11
C1
FWD
CM
X1(Hz/Hz1)
CM
FAB (MCCB)
Manual frequency
setting device
0 to 1k
Ω
Current input for automatic
setting (from the monitoring
room) (4 to 20mA)
Relay for operation
command
FX
Relay for switching the
frequency setting method
P1
P(+)
N(-)
U
V
W
30C
30B
30A
30
Y5C
Y5A
Y1
CME
G
DC REACTOR
(DCR)
Keypad panel
FRN G11S-
VR
(+)
(-)
Hz2/Hz1
FRN P11S-
RUN
RUN
Chapter6-10(P20˜21).p65
07.8.9, 12:52
Page 20
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......