Chapter 3
13. Power Regenerative PWM Converter (RHC)
3-24
■
Common specifications
Control
Control method
Sinusoidal wave input current control
Operation method
Operation starts at power-on after wiring completed
Input signal: Run command, Stop command, Reset input
Operation status signal
Ready to operate
Input power-factor
0.95 or higher (at 100% load)
Input harmonic current
Conversion coefficient Ki=0 (based on "Guideline for Harmonic Current Suppression" by MITI
"Ministry of International Trade and Industry")
Automatically restarts the converter at power recovery
Current limiting control
Controls current under the preset current limiting level.
Indication
Running, stopping
Input current, Input voltage, Input power, Output voltage (by 7-segment LED display)
Program mode
Displays function codes and data
Trip mode
Displays cause of the trip by code (by 7-segment LED display).
LD1 (LED) is on when CPU error occurs.
Protection
Overcurrent
Detects AC overcurrent to stop the operation of the unit. (OC)
Overvoltage
Detects DC overvoltage to stop the operation of the unit. (OV)
Overload
Stops operation of the unit by electronic thermal function and detection of temperature inside (OL)
Overheating
Stops operation of the unit by detecting heat sink overheating. (OH)
AC fuse blown
Stops operation of the unit by detecting AC fuse blown. (AFUS) *1)
DC fuse blown
Stops operation of the unit by detecting DC fuse blown. (DFUS) *1)
Abnormal frequency
Stops operation of the unit by detecting frequency of AC input power at power-on. (FRE)
DC link circuit undervoltage Stops operation of the unit when the DC voltage drops below the undervoltage level
(165V or less in 230V seires, 365V or less in 460V seires). (Auto-reset is selectable by function setting.) (LU)
AC circuit undervoltage
Stops operation of the unit when the AC voltage drops below the undervoltage level
(165V or less in 230V seires, 365V or less in 460V seires). (Auto-reset only, No alarm indication)
Installation location
Indoor use only. Altitude: 3300ft (1000m) or less. Free from corrosive gases, flammable gases, dusts,
and direct sunlight.
Ambient temperature
-20 to +50°C (-4 to 122°F)
Ambient humidity
20 to 90%RH (non-condensing)
Vibration
5.9m/s2 or less
Storage condition
-20 to +65°C (-4 to 149°F)
Restart after momentary
power failure
Condition
(Installation
and
operation)
*1) Not provided with RHC22- or smaller model.
3-12-13(P23˜30).65p
07.8.9, 12:34
Page 24
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......