1-30
Chapter 1
3. Wiring Diagram
Caution
The information described in this document is for the purpose of selecting the
appropriate product only. Before actually using this product, be sure to read the
Instruction Manual carefully to ensure proper operation.
(2) 230V/460V
FRENIC5000G11S : 2 to 10HP
FRENIC5000P11S : 7.5 to 15HP
Auxiliary control
power supply (*6)
L1/R
L2/S
L3/T
U
V
W
G
G
G
M
N(-)
P1
(X9)
(CM)
(FMP)
(DX-)
(DX+)
(SD)
(X1)
(FWD)
(REV)
(CM)
(X8)
<
Y5C
>
<
Y5A
>
<
Y4
>
<
Y3
>
<
Y2
>
<
Y1
>
<
CME
>
(X7)
(X6)
(X5)
(X4)
(X3)
(X2)
0V
0V
+10Vdc
+24Vdc
+0
〜
10Vdc
[13]
[12]
[11]
[C1]
[FMA]
P(+)
Power supply ( *1)
3-phase
200 to 230V
50/60Hz
or
3-phase
400 to 480V
50/60Hz
Main circuit
Grounding
(*7)
Control circuit
Digital input
RS-485
Pulse output
Motor
Transistor output
Relay output
(*1) Use the inverter whose rated input voltage
matches the power supply voltage.
DBR(*8)
(*7)
(R0)
(T0)
NOTE: Common terminals [11], (CM), and <CME> for
control circuits are isolated from one another.
SR
3
2
1
(+)
(–)
60Hz
(pulse counter) (*2)
Digital frequency meter
FM (*2)
0 to 60Hz
Analog frequency meter
4 to 20mAdc
Current input
It is possible to input voltage
signals (0 to +10Vdc or 0 to
+5Vdc) to terminals [12]-[11]
instead of the potentiometer.
0 to 10Vdc
Voltage input
Potentiometer
power supply (*2)
Analog input
DC REACTOR (DCR)
(*2) (*4)
(*3) Use this peripheral device when necessary.
(*2) An optional device. Use it when necessary.
DB
DB
P
G
(*6) Even if these terminals are not powered,
the inverter can be operated.
(*7) Terminal for grounding the motor.
Connect it, if necessary.
(*5) A built-in braking resistor (DBR)(*8) is
connected to the inverter before shipping.
DBR is not mounted on P11S models of 7.5
to 15HP.
When connecting an optional external braking
resistor (DB), remove the DBR connection
cables from [P(+)] and [ DB].
The end of removed cables(indicated with
an X) must be insulated.
(*4) When connecting a DC REACTOR (DCR),
remove the jumper wire (*7) that connects
the terminals [P1] and [P(+)].
Alarm otuput (for any fault)
2
1
External braking resistor (DB) (*2) (*5)
(CM)
(THR)
(PLC)
30A
30B
30C
30
M C C B
or
G F C I
MC
(*3)
(*3)
Chapter01J(P19˜32).p65
07.8.9, 11:53
Page 30
Adobe PageMaker 6.5J/PPC
Summary of Contents for FRENIC5000G11S Series
Page 1: ......
Page 2: ......
Page 154: ...3 30 3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC...
Page 166: ...4 12...
Page 182: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 5 16...
Page 212: ...3 12 13 P23 30 65p 07 8 9 12 34 Page 30 Adobe PageMaker 6 5J PPC 6 30...
Page 234: ...MEMO Chapter8 4 P15 p65 07 8 9 12 57 Page 18 Adobe PageMaker 6 5J PPC...
Page 235: ......
Page 236: ......