Falcon
M-Class
| User Guide
55
4.6.3
Navigating the MAC Table
Each page shows up to 999 entries from the MAC table, default being 20, selected through the
"entries per page" input field.
When first visited, the web page will show the first 20 entries from the beginning of the MAC Table.
The first displayed will be the one with the lowest VLAN ID and the lowest MAC address found in
the MAC Table.
The "Start from MAC address" and "VLAN" input fields allow the user to select the starting point in
the MAC Table.
Table 4-21: MAC Address Table Configuration Parameters
Start from VLAN
An input field that allows the user to select VLAN starting point in
the MAC Table.
MAC address
An input field that allows the user to select the MAC address starting
point in the MAC Table.
Clicking the Refresh button will update the displayed table starting from that or the
closest next MAC Table match.
In addition, click on Refresh, the Start from VLAN and MAC address fields assume
the value of the first displayed entry, allowing for continuous refresh with the same
start address.
The
>>
button will use the last entry of the currently displayed VLAN/MAC address
pairs as a basis for the next lookup.
When the end is reached the text “no more entries” is shown in the displayed table.
Use the
<<
button to start over.
Entries per page
An input field which sets the number of entries per page.
The default entry is 20 but can display up 999 entries from the
MAC table.
The first entry displayed will be the one with the lowest VLAN
ID and the lowest MAC address found in the MAC Table.
MAC Table Columns
Type
Indicates whether the entry is a static or dynamic entry.
VLAN
The VLAN ID of the entry.
MAC Address
The MAC address of the entry.
Port Members
The ports that are members of the entry.
Buttons
Auto-refresh
:
Automatic refresh occurs every 3 seconds.
Refresh:
Refreshes the displayed table starting from the "Start
from MAC address" and "VLAN" input fields.
Clear:
Flushes all dynamic entries.
<<:
Updates the table starting from the first entry
in the MAC Table, i.e. the entry with the lowest VLAN ID
and MAC address.
>>:
Updates the table, starting with the entry
after the last entry currently displayed.
Summary of Contents for Falcon Gen-3 M-Class
Page 90: ...Falcon M Class User Guide 90...
Page 107: ...Falcon M Class User Guide 107 Figure 4 57 DSCP Translation...
Page 139: ...Falcon M Class User Guide 139...
Page 187: ...Falcon M Class User Guide 187 Figure 4 99 RADIUS Statistics for Server...
Page 197: ...Falcon M Class User Guide 197 4 11 6 SyncCenter Status Figure 4 104 Sync Center Status...
Page 214: ...Falcon M Class User Guide 214...
Page 227: ...Falcon M Class User Guide 227...
Page 234: ...Falcon M Class User Guide 234...
Page 358: ...Falcon M Class User Guide 358 Figure 4 216 sFlow Configuration displays...
Page 376: ...Falcon M Class User Guide 376...
Page 403: ...Falcon M Class User Guide 403...