Falcon
M-Class
| User Guide
236
Transmit Hold
Count
The number of BPDU's a bridge port can send per second.
When exceeded, transmission of the next BPDU will be delayed. Valid
values are in the range 1 to 10 BPDU's per second.
Advanced Settings
Edge Port
BDPU Filtering
Controls whether a port,
explicitly
configured as
Edge,
will transmit and
receive BPDUs.
Edge Port
BPDU Guard
Control whether a port, explicitly configured as
Edge,
will disable itself
upon reception of a BPDU.
The port will enter the error-disabled state, and will be removed from the
active topology.
Port Error
Recovery
Control whether a port in the error-disabled state automatically will be
enabled after a certain time.
If recovery is not enabled, ports have to be disabled and re-enabled for
normal STP operation.
This condition is also cleared by a system reboot.
Port Error
Recovery
Timeout
The time that has to pass before a port in the error-disabled state can be
enabled.
Valid values are between 30 and 86400 seconds (24 hours).
Buttons
Save:
Click to save changes.
Reset:
Click to undo any changes made locally and revert to previously saved
values.
Summary of Contents for Falcon Gen-3 M-Class
Page 90: ...Falcon M Class User Guide 90...
Page 107: ...Falcon M Class User Guide 107 Figure 4 57 DSCP Translation...
Page 139: ...Falcon M Class User Guide 139...
Page 187: ...Falcon M Class User Guide 187 Figure 4 99 RADIUS Statistics for Server...
Page 197: ...Falcon M Class User Guide 197 4 11 6 SyncCenter Status Figure 4 104 Sync Center Status...
Page 214: ...Falcon M Class User Guide 214...
Page 227: ...Falcon M Class User Guide 227...
Page 234: ...Falcon M Class User Guide 234...
Page 358: ...Falcon M Class User Guide 358 Figure 4 216 sFlow Configuration displays...
Page 376: ...Falcon M Class User Guide 376...
Page 403: ...Falcon M Class User Guide 403...