Falcon
M-Class
| User Guide
53
Table 4-20: MAC Address Table Configuration Parameters
Aging Configuration
Aging
Configuration
By default, dynamic entries are removed from the MAC after 300 seconds.
This removal is also called aging.
Configure aging time by entering a value here in seconds; for example,
Age Time
: seconds
The allowed range is 10 to 10000000 seconds.
Check this box to disable the automatic aging of dynamic entries.
Disable Automatic Aging
MAC Table Learning
MAC Table
Learning
If the learning mode for a given port is grayed out, another module is in
control of the mode, so that it cannot be changed by the user. An example
of such a module is the MAC-Based Authentication under 802.1X. Each
port is capable of learning based upon the following settings:
Auto
: Learning is done automatically as soon as a frame with an unknown
SMAC is received.
Disable
: No learning is done.
Secure
: Only static MAC entries are learned, all other frames are
dropped.
Note:
Make sure that the link used for managing the switch is added
to the Static Mac Table before changing to secure learning mode,
otherwise the management link is lost and can only be restored by using
another non-secure port or by connecting to the switch via the serial
interface.
Static MAC Table Configuration
Static MAC Table
Configuration
The static entries in the MAC table are shown in this table
The static MAC table can contain up to a maximum 64 entries
The MAC table is sorted first by VLAN ID and then by MAC address.
Delete
: Check to delete the entry. It will be deleted during the next save.
VLAN ID
: The VLAN ID for the entry.
MAC Address
: The MAC address for the entry.
Port Members
: Checkmarks indicate which ports are members of the
entry. Check or uncheck as needed to modify the entry.
Add a new static entry:
Click to Add New Static Entry to add a new
entry to the static MAC table. Specify the VLAN ID, MAC address, and port
members for the new entry.
Click "Save".
Buttons
Save:
Click to save changes
Reset:
Click to undo any changes made locally and revert to previously saved
values.
Summary of Contents for Falcon Gen-3 M-Class
Page 90: ...Falcon M Class User Guide 90...
Page 107: ...Falcon M Class User Guide 107 Figure 4 57 DSCP Translation...
Page 139: ...Falcon M Class User Guide 139...
Page 187: ...Falcon M Class User Guide 187 Figure 4 99 RADIUS Statistics for Server...
Page 197: ...Falcon M Class User Guide 197 4 11 6 SyncCenter Status Figure 4 104 Sync Center Status...
Page 214: ...Falcon M Class User Guide 214...
Page 227: ...Falcon M Class User Guide 227...
Page 234: ...Falcon M Class User Guide 234...
Page 358: ...Falcon M Class User Guide 358 Figure 4 216 sFlow Configuration displays...
Page 376: ...Falcon M Class User Guide 376...
Page 403: ...Falcon M Class User Guide 403...