3. Installation
3−29
Festo P.BE−MPA−EN en 0502b
3.4.3
MPA valve terminal with MPM connection
Assign the addresses in ascending order without gaps
(see example)
Addess assignment does not depend on whether blanking
plates or valve plates are fitted.
Depending on the electronic module, a valve location oc
cupies the following number of addresses:
Number
f dd
Electronic module
of addresses
MPA 1
MPA 2
one address
VMPA1−MPM−EMM−
4
VMPA2−MPM−EMM−
2
two addresses
VMPA1−MPM−EMM−
8
VMPA2−MPM−EMM−
4
Table3/7:
Electronic module for MPM connection
If an electronic module occupies 2 addresses, the follow
ing applies:
pilot solenoid 14 occupies the lower−value address;
pilot solenoid 12 occupies the higher−value address.
Summary of Contents for MPA-FB Series
Page 2: ......
Page 4: ...Contents and general instructions II Festo P BE MPA EN en 0502b...
Page 8: ...Contents and general instructions VI Festo P BE MPA EN en 0502b...
Page 17: ...Summary of components 1 1 Festo P BE MPA EN en 0502b Chapter 1...
Page 30: ...1 Summary of components 1 14 Festo P BE MPA EN en 0502b...
Page 31: ...Fitting 2 1 Festo P BE MPA EN en 0502b Chapter 2...
Page 47: ...Installation 3 1 Festo P BE MPA EN en 0502b Chapter 3...
Page 55: ...3 Installation 3 9 Festo P BE MPA EN en 0502b 1 2 3 Fig 3 2 Disconnecting the tubing...
Page 79: ...Commissioning 4 1 Festo P BE MPA EN en 0502b Chapter 4...
Page 96: ...4 Commissioning 4 18 Festo P BE MPA EN en 0502b...
Page 97: ...Diagnosis and error treatment 5 1 Festo P BE MPA EN en 0502b Chapter 5...
Page 139: ...Technical appendix A 1 Festo P BE MPA EN en 0502b Appendix A...
Page 151: ...Accessories B 1 Festo P BE MPA EN en 0502b Appendix B...
Page 161: ...Index C 1 Festo P BE MPA EN en 0502b Appendix C...
Page 162: ...C Index C 2 Festo P BE MPA EN en 0502b Contents C Index C 1...