UFS8000
Service
99
23.6.6. Media
Attention !
This chapter only applies to control unit type UFS8x1x.
In this screen the RS232 port and the 485 port can be
controlled.
The send and receive lines can be controlled independently.
The counter behind “Rx” (receive line) is increased by 1 each time a “COMTEST” message is sent by
the control. This message can be sent, for example, via the PC “HyperTerminal” software (settings :
baudrate=9600,databits=8,stopbits=1, parity=no).
In “HyperTerminal” the text “COMTEST” then needs to be entered, after which the “Enter” key needs
to pressed.
A message containing the type of control and the serial number will be sent by pushing the text box
“Tx” of the targeted communication port. For example “UFS8000 750345” for a UFS8000 with serial
number 750345. If the message has been sent, the counter behind “Tx” will be increased by 1.