4.
Unscrew the three brass screws that secure the circuit board and center plate
assembly.
5.
Lift the circuit board and center plate assembly out of the source unit.
6.
De-solder the red and black chopper motor power wires from the circuit board.
7.
Unscrew and remove the three chopper motor screws (
).
Chopper Motor Assembly
Figure 5-6:
A. Chopper motor assembly
B. Chopper motor retaining screws
C. Center plate
8.
Install the new chopper motor and retaining screws removed in
.
9.
Solder the chopper motor power wires to the circuit board. Solder the red wire to
the M+ terminal and the black wire to the M- terminal.
10.
Install the center plate and circuit board assembly. Secure the assembly with the
three brass crews removed in
.
11.
Line up and install the window plate onto the source unit. Fully seat the window
plate flange in the source unit.
12.
Secure the source unit to the air purge using the four screws removed in
.
Tighten the screws evenly.
13.
Power up the Rosemount CCO 5500 Analyzer and check the chopper motor
frequency in Mode
4
(
DIAGNOSTICS
). Adjust using the trim potentiometer as
described in
Maintenance
Reference Manual
85
Summary of Contents for Rosemount CCO 5500
Page 4: ......
Page 8: ...Contents iv Rosemount CCO 5500 ...
Page 28: ...System Wiring Diagram Figure 2 7 Install 20 Rosemount CCO 5500 ...
Page 32: ...Install 24 Rosemount CCO 5500 ...
Page 88: ...Operation 80 Rosemount CCO 5500 ...
Page 98: ...Maintenance 90 Rosemount CCO 5500 ...
Page 108: ...Troubleshooting 100 Rosemount CCO 5500 ...
Page 110: ...Spare parts 102 Rosemount CCO 5500 ...
Page 122: ...Return equipment to the factory 114 Rosemount CCO 5500 ...
Page 123: ...Return equipment to the factory Reference Manual 115 ...