Figure 3-5: Bolted band shroud meter assembly - bottom view
A. 5/16”-18UNC bolts and lock washers
Procedure
1. Use the 1/2 wrench to loosen and remove one of the bolted band shroud bolts and
lock washer while holding the band shroud to prevent spring back of the shroud.
2. Loosen and remove the second bolted band shroud bolt with lock washer using the
1/2" wrench.
3. Spread the band shroud apart and remove from the body and place the circular
edge on a flat surface.
4. Use the 1/2" wrench and remove the two end shroud bolts with lock washers while
holding the end shrouds in position. As the bolts are loosened, remove both end
shrouds and place on a flat surface.
5. Repeat Steps 1 through 4 to remove the other band shroud.
6. Move the shroud parts, bolts and lock washers out of your immediate work area.
This completes the bolted band shroud removal procedure.
3.4.2
Remove clamped band shrouds
WARNING
CUTTING HAZARD
Sharp edges may be present on the band shrouds.
Wear appropriate personal protective equipment when working on the meter.
Failure to comply may cause serious injury.
Table 3-3: Clamped band shroud removal tool list
Tools required
Standard
½
inch socket or a standard
½
inch wrench
Flat blade screw driver or 5/16 inch nut driver
Appropriate personal protective equipment
Meter maintenance
Maintenance and Troubleshooting Manual
April 2022
00809-0100-3812
44
Emerson.com/Rosemount