FAP54 Programming
145
Code
Error
60
Auto-addressed open mode initialization: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
61
Auto-addressed open mode initialization: unexpected voltage on line LB.
A voltage on LB clamps has been detected at the beginning of the initialization procedure; this voltage is probably
due to an unwanted connection between line LA and line LB.
62
Auto-addressed open mode initialization: lack of 4 consecutive addresses to assign to a multiple I/O module.
65
Auto-addressed open mode initialization: missing answer from a device with invalid address.
The module could not communicate with the device: check the electrical connections.
66
Auto-addressed open mode initialization: Missing answer from a device with valid (1 – 128) address.
The module could not communicate with the device: check the electrical connections.
67
Auto-addressed open mode initialization: line fault (overload / short circuit) after device addressing or acquisition.
Check the electrical connections after the just addressed/acquired device.
70
Auto-addressed open mode initialization: unexpected voltage is found on LB while the procedure is in progress on
line LA.
Check that the detection line connected to LA is not connected to LB.
71
Auto-addressed open mode initialization: no answer from the device during the address assignment phase.
Check the electrical connections after the device.
72
Auto-addressed open mode initialization: device with random address not found.
Check the electrical connections.
80
Pre-configured open mode initialization: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
87
Pre-configured open mode initialization: line fault (overload / short circuit) after device addressing or acquisition.
Check the electrical connections after the just addressed/acquired device.
88
Pre-configured open mode initialization: maximum number of devices reached.
Warning: do not overcome the limit of max 128 devices per line.
89
Pre-configured open mode initialization: there is a device with invalid address.
The procedure only works with devices having valid addresses (range 1 – 128).
100
Update open mode initialization: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
102
Update open mode initialization: lack of 4 consecutive addresses to assign to a multiple I/O module.
106
Update open mode initialization: missing answer from a device with valid (1 – 128) address.
The module could not communicate with the device: check the electrical connections.
107
Update open mode initialization: line fault (overload / short circuit) after device addressing or acquisition.
Check the electrical connections after the just addressed/acquired device.
108
Update open mode initialization: maximum number of devices reached.
Warning: do not overcome the limit of max 128 devices per line.
109
Update open mode initialization: the maximum number of addressed devices has been reached and there are
other devices not addressed yet on the line.
Warning: do not overcome the limit of max 128 devices per line.
110
Update open mode initialization: reached the maximum number of generated random addresses.
Repeat the procedure and/or manually address the devices not yet addressed.
111
Update open mode initialization: the line is empty.
Check the electrical connections.
160
Procedure of device programming: no answer from the device.
180
Walk addressing: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
182
Walk addressing: lack of 4 consecutive addresses to assign to a multiple I/O module.
184
Walk addressing: simultaneous answer from more than one device.
Check the electrical connections, the connection of the detectors on their base and the power supply jumpers for
each single module and manual call point.
186
Walk addressing: missing answer from a device with valid (1 – 128) address.
The module could not communicate with the device: check the electrical connections.
193
Walk addressing: procedure stopped because of a stop command coming from the control panel
200
Search for multiple addresses procedure: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
201
Search for multiple addresses procedure: found a duplicated address.
205
Type match verification procedure: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.
206
Type match verification procedure: mismatch between the configuration stored in the control panel and the
configuration in the field.
207
Search short circuit: line fault (overload or shortcircuit) at power on.
Check the electrical connections among the circuit line card and the devices connected directly with LA and LB.