Maintenance, 10h
IPL350TD-1EN2.pdf
2012-06-18
Check level, radiator
Fig. Cooler
Check the radiator level daily. Coolant should be
changed once/year.
Release the pressure before opening the radiator
cap!
Release the pressure before opening the radiator
cap!
Brake function/Emergency stop - Check
Fig. Control panel
1. Emergency stop
2. Forward/Reverse lever
1
2
Checking the emergency stop
Drive the planer
slowly
forward. Hold the steering
wheel firmly and brace yourself for a sudden stop.
Push in the emergency stop (1). The planer should
come to a sudden stop and the engine should switch
off.
After checking the emergency stop, set the
forward/reverse lever (2) in neutral.
Pull up the emergency stop (1). Start the engine.
The planer is now ready for operation.
See also Operating section in the manual.
76
Summary of Contents for PL350 TD
Page 2: ......
Page 16: ...Safety Optional IPL350TD 1EN2 pdf 2012 06 18 8 ...
Page 20: ...Special instructions IPL350TD 1EN2 pdf 2012 06 18 12 ...
Page 66: ...Long term parking IPL350TD 1EN2 pdf 2012 06 18 58 ...
Page 72: ...Preventive maintenance IPL350TD 1EN2 pdf 2012 06 18 64 ...
Page 96: ...Maintenance 250h IPL350TD 1EN2 pdf 2012 06 18 88 ...
Page 106: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden ...
Page 107: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden ...