Water filter - Checking/Replacing
Fig. Water filter
1. Filter unit
2. Air valve
1
2
The filter unit (1) must be replaced when it indicates a
strong brown color.
- Check that the water pump is not in operation.
- Release the sight glass by hand and remove the old
filter unit.
- Clean the filter glass.
- Fit a new filter unit, and tighten the sight glass by
hand.
- If necessary, bleed the filter by opening the air valve
(2) when the water pump is in operation.
Check after replacing that the seal is correctly
positioned!
Always dispose of old filters. Never reuse!
Always dispose of old filters. Never reuse!
Recycle old filters for waste disposal!
Recycle old filters for waste disposal!
Clean cooler
Fig. Cooler
Make sure that the air flow through the cooler is
unobstructed. Dirty coolers are blown clean with
compressed air or washed clean using a
high-pressure water cleaner.
Take care when using a high-pressure water jet.
Do not hold the nozzle too near the cooler.
Take care when using a high-pressure water jet.
Do not hold the nozzle too near the cooler.
Wear protective goggles when working with
compressed air or high-pressure water jets.
Wear protective goggles when working with
compressed air or high-pressure water jets.
75
Summary of Contents for PL350 TD
Page 2: ......
Page 16: ...Safety Optional IPL350TD 1EN2 pdf 2012 06 18 8 ...
Page 20: ...Special instructions IPL350TD 1EN2 pdf 2012 06 18 12 ...
Page 66: ...Long term parking IPL350TD 1EN2 pdf 2012 06 18 58 ...
Page 72: ...Preventive maintenance IPL350TD 1EN2 pdf 2012 06 18 64 ...
Page 96: ...Maintenance 250h IPL350TD 1EN2 pdf 2012 06 18 88 ...
Page 106: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden ...
Page 107: ...Dynapac Compaction Equipment AB Box 504 SE 371 23 Karlskrona Sweden ...